Structural Health Monitoring Using Statistical Process Control
Abstract
This paper poses the process of structural health monitoring in the context of a statistical pattern recognition paradigm. This paper particularly focuses on applying a statistical process control (SPC) technique known as an “X-bar control chart” to vibration-based damage diagnosis. A control chart provides a statistical framework for monitoring future measurements and for identifying new data that are inconsistent with past data. First, an autoregressive (AR) model is fit to the measured time histories from an undamaged structure. Coefficients of the AR model are selected as the damage-sensitive features for the subsequent control chart analysis. Next, control limits of the X-bar control chart are constructed based on the features obtained from the initial structure. Finally, the AR coefficients of the models fit to subsequent new data are monitored relative to the control limits. A statistically significant number of features outside the control limits indicate a system transition from a healthy state to a damage state. A unique aspect of this study is the coupling of various projection techniques such as principal component analysis and linear and quadratic discriminant operators with the SPC in an effort to enhance the discrimination between features from the undamaged and damaged structures. This combined statistical procedure is applied to vibration test data acquired from a concrete bridge column as the column is progressively damaged. The coupled approach captures a clearer distinction between undamaged and damaged vibration responses than by applying an SPC alone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Time Series Analysis: Forecasting and Control
Geurts, M., Box, G. E. P., & Jenkins, G. M. (1977) · Journal of Marketing Research · doi:10.2307/3150485 · Cited by 19,186
Neural networks for pattern recognition
(1994) · Choice Reviews Online · doi:10.5860/choice.31-5500 · Cited by 18,538
Introduction to Statistical Pattern Recognition
(1990) · Elsevier eBooks · doi:10.1016/c2009-0-27872-x · Cited by 11,031
Introduction to Statistical Quality Control
Sauter, R. M., & Montgomery, D. C. (1992) · Technometrics · doi:10.2307/1269251 · Cited by 7,842
Time Series Analysis: Forecasting and Control.
Anderson, O. D., Box, G. E. P., & Jenkins, G. M. (1978) · The Statistician · doi:10.2307/2988198 · Cited by 5,298
Time Series: Theory and Methods
Ziegel, E. R., Brockwell, P., & Davis, R. (1992) · Technometrics · doi:10.2307/1270070 · Cited by 5,012
Time Series: Theory and Methods
Brockwell, P. J., & Davis, R. A. (1991) · Springer Series in Statistics · doi:10.1007/978-1-4419-0320-4 · Cited by 4,122
Multivariate Density Estimation: Theory, Practice, and Visualization
Scott, D. W. (1992) · Wiley Series in Probability and Statistics · doi:10.1002/9780470316849 · Cited by 3,696
A Summary Review of Vibration-Based Damage Identification Methods
Doebling, S. W., Farrar, C. R., & Prime, M. B. (1998) · The Shock and Vibration Digest · doi:10.1177/058310249803000201 · Cited by 2,823
Self-citationMultivariate Density Estimation, Theory, Practice, and Visualbation
Ramsay, P. H. (1993) · Technometrics · doi:10.1080/00401706.1993.10485361 · Cited by 2,789
Cited by
Emerging Artificial Intelligence Methods in Structural Engineering
Salehi, H., & Burgueño, R. (2018) · Engineering Structures · doi:10.1016/j.engstruct.2018.05.084 · Cited by 1,068
Gul, M., & Necati Catbas, F. (2009) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2009.02.013 · Cited by 311
Widodo, A., Yang, B.-S., & Han, T. (2007) · Expert Systems with Applications · doi:10.1016/j.eswa.2005.11.031 · Cited by 296
Data-Driven Structural Health Monitoring Using Feature Fusion and Hybrid Deep Learning
Dang, H. V., Tran-Ngoc, H., Nguyen, T. V., Bui-Tien, T., De Roeck, G., & Nguyen, H. X. (2021) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2020.3034401 · Cited by 170
Farreras-Alcover, I., Chryssanthopoulos, M. K., & Andersen, J. E. (2015) · Structural Health Monitoring · doi:10.1177/1475921715609801 · Cited by 58
Metadata
- Authors
- Sohn, H., Czarnecki, J. A., & Farrar, C. R.
- Venue
- Journal of Structural Engineering
- Published
- 2000-11
- Volume
- 126
- Issue
- 11
- Pages
- 1356-1363
- ISSN
- 0733-9445 (ISSN-L)
- 1943-541X
- DOI
- 10.1061/(asce)0733-9445(2000)126:11(1356
- OpenAlex
- W2090629586
- Cited by
- 347
- References
- 15
- FWCI
- 15.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Structural Health Monitoring Using Statistical Process Control. https://app.cochat.ai/papers/10.1061/(asce)0733-9445(2000)126:11(1356
- The paper
- Sohn, H., Czarnecki, J. A., & Farrar, C. R. (2000). Structural Health Monitoring Using Statistical Process Control. Journal of Structural Engineering. https://doi.org/10.1061/(asce)0733-9445(2000)126%3A11(1356
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.