Optimum Absorber Parameters for Tuned Liquid Column Dampers
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Tuned liquid column dampers (TLCDs) are a class of tuned liquid dampers that impart indirect damping to the primary structure through oscillations of the liquid column in a U-shaped container. The energy dissipation in the water column results from the passage of the liquid through an orifice with inherent head-loss characteristics. The overall damping in a TLCD depends on the head-loss coefficient and the velocity of the oscillating liquid, and it is nonlinear due to the quadratic damping term. Using the TLCD theory and the equivalent linearization scheme, a new approach has been developed that helps to compute the optimum head-loss coefficient for a given level of wind or seismic excitation in a single step, without resorting to iterations. The optimal damping coefficient and tuning ratio of a TLCD using a single degree of freedom system under the white noise and a set of filtered white noise excitations representing wind and seismic loadings is presented. Optimum values of damping have also been investigated for multiple TLCDs. An example is presented to demonstrate the performance of multiple TLCDs in controlling multiple modes under wind excitation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
BISHOP, R. E. D. (1957) · Nature · doi:10.1038/179504a0 · Cited by 1,636
Applied Fluid Dynamics Handbook
Blevins, R. D. (1984) · Cited by 1,178
Optimum absorber parameters for various combinations of response and excitation parameters
Warburton, G. B. (1982) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290100304 · Cited by 1,043
Passive energy dissipation systems in structural engineering
Crewe, A. (1998) · Structural Safety · doi:10.1016/s0167-4730(97)00034-9 · Cited by 1,015
Random vibration and statistical linearization
Roberts, J. B., & Spanos, P. D. (1990) · Cited by 999
Optimization Toolbox User's Guide
Coleman, T. F., Branch, M. A., & Grace, A. (1998) · Cited by 881
Passive Energy Dissipation Systems in Structural Engineering
Dargush, G. F., & Soong, T. T. (1997) · Medical Entomology and Zoology · Cited by 880
Random vibration and statistical linearization
Robson, J. D. (1990) · Journal of Sound and Vibration · doi:10.1016/0022-460x(90)90647-i · Cited by 822
Parametric study and simplified design of tuned mass dampers
Rana, R., & Soong, T. T. (1998) · Engineering Structures · doi:10.1016/s0141-0296(97)00078-3 · Cited by 651
Optimum absorber parameters for simple systems
Warburton, G. B., & Ayorinde, E. O. (1980) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290080302 · Cited by 368
Cited by
Gutierrez Soto, M., & Adeli, H. (2013) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-013-9091-7 · Cited by 346
Modelling and preliminary design of a structure-TLD system
Tait, M. J. (2008) · Engineering Structures · doi:10.1016/j.engstruct.2008.02.017 · Cited by 215
Semi-active tuned liquid column dampers for vibration control of structures
Yalla, S. K., Kareem, A., & Kantor, J. C. (2001) · Engineering Structures · doi:10.1016/s0141-0296(01)00047-5 · Cited by 164
Self-citationStructural control and vibration issues in wind turbines: A review
Xie, F., & Aly, A.-M. (2020) · Engineering Structures · doi:10.1016/j.engstruct.2019.110087 · Cited by 159
Min, K.-W., Kim, J., & Lee, H.-R. (2014) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/j.jweia.2014.03.003 · Cited by 38
Ruiz, R. O., Taflanidis, A. A., & Lopez-Garcia, D. (2016) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2016.01.014 · Cited by 32
Compliant liquid column damper modified by shape memory alloy device for seismic vibration control
Gur, S., Mishra, S. K., Bhowmick, S., & Chakraborty, S. (2014) · Smart Materials and Structures · doi:10.1088/0964-1726/23/10/105009 · Cited by 30
Metadata
- Authors
- Yalla, S. K., & Kareem, A.
- Venue
- Journal of Structural Engineering
- Published
- 2000-08
- Volume
- 126
- Issue
- 8
- Pages
- 906-915
- ISSN
- 0733-9445 (ISSN-L)
- 1943-541X
- DOI
- 10.1061/(asce)0733-9445(2000)126:8(906
- OpenAlex
- W2004823537
- Cited by
- 224
- References
- 21
- FWCI
- 11.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.