The DOI matches its Crossref record.
Experimental Behavior of High Strength Square Concrete-Filled Steel Tube Beam-Columns
Abstract
The flexural force-deformation behavior of high strength square concrete-filled steel tube (CFT) beam-columns was experimentally investigated. The parameters in the study included the width-to-thickness (b/t) ratio, the yield stress (σy) of the steel tube, and the axial load level. Eight CFT beam-column specimens were tested under constant axial load and monotonically increasing flexural loading. The CFT specimens were 305-mm square tubes with nominal b/t ratios of 32 or 48, made from either conventional (A500 Grade-B) or high strength (A500 Grade-80) steel, and filled with high strength (110 MPa) concrete. Experimental results indicate that the moment capacity of CFT beam-columns is reached as inelastic behavior of the steel tube and concrete infill is combined with local buckling of the steel tube and crushing of the concrete. The moment capacity of high strength square CFT beam-columns can be predicted with reasonable accuracy using the current American Concrete Institute code provisions for composite columns. The curvature ductility of high strength square CFT beam-columns decreases significantly with an increase in either the axial load level or the b/t ratio of the steel tube. The yield stress of the steel tube does not seem to have a significant influence on curvature ductility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Design of Concrete Filled Tubular Beam-columns with High Strength Steel and Concrete
Liew, J. Y. R., Xiong, M., & Xiong, D. (2016) · Structures · doi:10.1016/j.istruc.2016.05.005 · Cited by 262
Ultra-High Strength Concrete Filled Composite Columns for Multi-Storey Building Construction
Liew, J. Y. R., & Xiong, D. X. (2012) · Advances in Structural Engineering · doi:10.1260/1369-4332.15.9.1487 · Cited by 170
Behaviour of steel tubular members infilled with ultra high strength concrete
Xiong, M.-X., Xiong, D.-X., & Liew, J. Y. R. (2017) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2017.07.001 · Cited by 156
Metadata
- Authors
- Varma, A. H., Ricles, J. M., Sause, R., & Lu, L.-W.
- Venue
- Journal of Structural Engineering
- Published
- 2002-03
- Volume
- 128
- Issue
- 3
- Pages
- 309-318
- ISSN
- 0733-9445 (ISSN-L)
- 1943-541X
- DOI
- 10.1061/(asce)0733-9445(2002)128:3(309
- OpenAlex
- W2072700103
- Cited by
- 203
- References
- 0
- FWCI
- 28.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Experimental Behavior of High Strength Square Concrete-Filled Steel Tube Beam-Columns. https://app.cochat.ai/papers/10.1061/(asce)0733-9445(2002)128:3(309
- The paper
- Varma, A. H., Ricles, J. M., Sause, R., & Lu, L.-W. (2002). Experimental Behavior of High Strength Square Concrete-Filled Steel Tube Beam-Columns. Journal of Structural Engineering. https://doi.org/10.1061/(asce)0733-9445(2002)128%3A3(309
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.