Steel Beam-Column Connections Using Shape Memory Alloys
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This study evaluates the feasibility of a new class of partially restrained connections using shape memory alloys. In the martensitic form, shape memory alloys (SMAs) have the ability to recover large residual deformations by heating the alloy above its transformation temperature. The proposed connection consists of four large diameter NiTi SMA bars connecting the beam flange to the column flange and serve as the primary moment transfer mechanism. Two full-scale connections were tested using the SAC loading protocol. The connections exhibited a high level of energy dissipation, large ductility capacity, and no strength degradation after being subjected to cycles up to 4% drift. Following the initial testing series, the tendons were heated to recover the residual beam tip displacement. After initiating the shape memory effect within the tendons, the connections were retested, displaying repeatable and stable hysteretic behavior. An additional test was performed under dynamic loading to examine the strain rate effects on the performance of the connection. The dynamic tests showed similar behavior, except for a decrease in energy dissipation capacity when compared to the quasi-static tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tadaki, T., Otsuka, K., & Shimizu, K. (1988) · Annual Review of Materials Science · doi:10.1146/annurev.ms.18.080188.000325 · Cited by 1,030
Base isolation system with shape memory alloy device for elevated highway bridges
Wilde, K., Gardoni, P., & Fujino, Y. (2000) · Engineering Structures · doi:10.1016/s0141-0296(98)00097-2 · Cited by 367
Active vibration control of flexible beams using shape memory actuators
Baz, A., Imam, K., & McCoy, J. (1990) · Journal of Sound and Vibration · doi:10.1016/0022-460x(90)90760-w · Cited by 206
Cited by
Alam, M. S., Youssef, M. A., & Nehdi, M. (2007) · Canadian Journal of Civil Engineering · doi:10.1139/l07-038 · Cited by 250
“Ocel et al. (2004) investigated the effectiveness of partially restrained steel beam–column connections using SMA elements.”
BackgroundMethodSelf‐centering seismic‐resistant structures: Historical overview and state‐of‐the‐art
Zhong, C., & Christopoulos, C. (2022) · Earthquake Spectra · doi:10.1177/87552930211057581 · Cited by 170
“Beam–column connections incorporating SMA rods were also developed for steel (Chowdhury et al., 2019; Ocel et al., 2004) and RC frames (Navarro-Gómez and Bonet, 2019; Youssef et al., 2008).”
MethodRecentering Shape Memory Alloy Passive Damper for Structural Vibration Control
Qian, H., Li, H., Song, G., & Guo, W. (2013) · Mathematical Problems in Engineering · doi:10.1155/2013/963530 · Cited by 82
Metadata
- Authors
- Ocel, J., DesRoches, R., Leon, R. T., Hess, W. G., Krumme, R., Hayes, J. R., & Sweeney, S.
- Venue
- Journal of Structural Engineering
- Published
- 2004-05
- Volume
- 130
- Issue
- 5
- Pages
- 732-740
- ISSN
- 0733-9445 (ISSN-L)
- 1943-541X
- DOI
- 10.1061/(asce)0733-9445(2004)130:5(732
- OpenAlex
- W2123729382
- Cited by
- 231
- References
- 3
- FWCI
- 30.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.