CoChat

Wind-Induced Motion Control of 76-Story Benchmark Building Using the Hybrid Damper-TLCD System

Kim, Hongjin, Adeli, Hojjat · 2005 · Journal of Structural Engineering
DOI 10.1061/(asce)0733-9445(2005)131:12(1794
Cited by 101

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The tuned liquid column damper (TLCD) has recently been advanced for vibration control of structures subjected to wind loading. The effectiveness of the semiactive TLCD system and the hybrid viscous fluid damper-TLCD control system recently proposed by the writers is investigated for control of wind-induced motion of high-rise buildings. Simulations are performed on a 76-story building benchmark control problem subjected to wind tunnel test data and stochastic wind loads. It is shown that the semiactive TLCD control system performs comparably to a sample active tuned mass damper (ATMD) system and thus is an attractive alternative to the ATMD system. More significantly, it is shown that the hybrid viscous fluid damper-TLCD system reduces the response of the building substantially more than the semiactive TLCD system at every natural frequency of the building. Furthermore, the hybrid damper-TLCD system is robust in terms of the stiffness modeling error for control of both displacement and acceleration responses. The simulation results show that the proposed hybrid viscous fluid damper-TLCD system can perform effectively under various wind loading conditions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1061/(asce)0733-9445(2005)131:12(1794)

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 101

Metadata

Authors
Kim, H., & Adeli, H.
Venue
Journal of Structural Engineering
Published
2005-12
Volume
131
Issue
12
Pages
1794-1802
ISSN
  • 0733-9445 (ISSN-L)
  • 1943-541X
DOI
10.1061/(asce)0733-9445(2005)131:12(1794
OpenAlex
W2071109779
Cited by
101
References
1
FWCI
3.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Wind-Induced Motion Control of 76-Story Benchmark Building Using the Hybrid Damper-TLCD System. https://app.cochat.ai/papers/10.1061/(asce)0733-9445(2005)131:12(1794
The paper
Kim, H., & Adeli, H. (2005). Wind-Induced Motion Control of 76-Story Benchmark Building Using the Hybrid Damper-TLCD System. Journal of Structural Engineering. https://doi.org/10.1061/(asce)0733-9445(2005)131%3A12(1794

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.