Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 170

The DOI matches its Crossref record.

Integrating a Global Positioning System and Accelerometers to Monitor the Deflection of Bridges

Roberts, Gethin Wyn, Meng, Xiaolin, Dodson, Alan Henry·2004·Journal of Surveying Engineering
DOI 10.1061/(asce)0733-9453(2004)130:2(65

Abstract

During the design phase of a bridge, certain characteristics are assumed, such as traffic and wind loading. In reality, however, these characteristics can vary, therefore it is very important that the health of such a structure is monitored to evaluate whether it is holding up to the true loading. Due to the ever-increasing size and cost of these structures, it is vital that any anomalies from the expected deflections are detected as soon as possible, allowing remedial action to be taken, and hence trying to prevent disastrous consequences. The use of a kinematic global positioning system (GPS) now allows subcentimeter accuracy to be achieved at a rate of up to 20 Hz, and at maximum distances from the reference GPS receivers to the bridge receivers of up to 20 km. This makes such a system capable of detecting the deflections of long bridges. In addition, accelerometers have been proven useful for such monitoring, allowing precise readings at rates of up to 1,000 Hz. However, both systems have their limitations. A GPS is limited partly by multipath and cycle slips, relatively low frequency of data, as well as the need to have good satellite coverage, while accelerometers are limited due to the fact that the derivations (velocities, displacements) from the original uncompensated acceleration readings will drift over time. The integration of the two systems, however, results in a hybrid arrangement that helps to eliminate the disadvantages of the two separate units. This paper presents an integrated monitoring system, consisting of Leica CRS1000 series and SR530 dual frequency code/carrier phase GPS receivers and a Kistler triaxial accelerometer. One of the SR530 GPS receivers and the accelerometer are physically integrated, and their data are synchronized. Using spectrum analysis, main natural frequencies of a monitored suspension footbridge are identified from the hybrid system. A simple data processing algorithm is presented, as well as the results from field trials to show the potential applications of such a system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1061/(asce)0733-9453(2004)130:2(65)

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Metadata

Authors
Roberts, G. W., Meng, X., & Dodson, A. H.
Venue
Journal of Surveying Engineering
Published
2004-05
Volume
130
Issue
2
Pages
65-72
ISSN
  • 0733-9453 (ISSN-L)
  • 1943-5428
DOI
10.1061/(asce)0733-9453(2004)130:2(65
OpenAlex
W2052300787
Cited by
170
References
0
FWCI
17.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Integrating a Global Positioning System and Accelerometers to Monitor the Deflection of Bridges. https://app.cochat.ai/papers/10.1061/(asce)0733-9453(2004)130:2(65
The paper
Roberts, G. W., Meng, X., & Dodson, A. H. (2004). Integrating a Global Positioning System and Accelerometers to Monitor the Deflection of Bridges. Journal of Surveying Engineering. https://doi.org/10.1061/(asce)0733-9453(2004)130%3A2(65

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.