CoChat

Disinfection Methods for Treating Low TOC, Light Graywater to California Title 22 Water Reuse Standards

Beck, Sara E., Rodríguez, Roberto A., Salveson, Andrew, Goel, Nitin, Rhodes, Sarah, Kehoe, Paula, Linden, Karl G. · 2013 · Journal of Environmental Engineering
Cited by 34

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

This research was performed as part of the San Francisco Public Utilities Commission’s search for more sustainable water resources. Disinfection methods were evaluated for treating light graywater to California drinking water standards for unrestricted, direct nonpotable water use, indoors. Graywater originating from sinks and showers in a commercial office building in southern California was collected in grab samples over 4 weeks. Samples were filtered and tested for disinfection efficacy toward indigenous total coliforms and Enterococci as well as seeded male-specific 2 (MS2) coliphage. The filtered samples were exposed to monochromatic (253.7 nm) ultraviolet (UV) light, chlorination with sodium hypochlorite, and ozonation. A UV dose of 100 mJ/cm2 completely inactivated Enterococci and inactivated total coliforms to California drinking water standards required levels and achieved 5-log reduction of MS2 in half of the samples. Sodium hypochlorite met bacteria and virus standards for the graywater at a free-chlorine concentration × time (CT) well below the 450 (mg/L)-min required by California drinking water standards. An ozone CT of 0.4 (mg/L)-min met bacteriological standards for reuse in two of the four samples. Ozone virus inactivation criteria was inconclusive due to the high-ozone demand of the water matrix when seeded with the test organism; however, an applied ozone dose of 5–7 mg/L would be expected to satisfy the ozone demand and meet the virus criteria. Of the disinfection options discussed, UV light was the least expensive, followed in order of lowest to highest cost by sodium hypochlorite delivered in bulk, sodium hypochlorite generated on-site, and ozone. An important and novel component of this research was that graywater treatment was performed only with tertiary processes and thus, biological treatment was not used. These results are applicable to other light graywaters with similar total organic carbon (TOC) concentrations (less than 5 mg/L as carbon).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1061/(asce)ee.1943-7870.0000738

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Beck, S. E., Rodríguez, R. A., Salveson, A., Goel, N., Rhodes, S., Kehoe, P., & Linden, K. G.
Venue
Journal of Environmental Engineering
Published
2013-09
Volume
139
Issue
9
Pages
1137-1145
ISSN
  • 0733-9372 (ISSN-L)
  • 1943-7870
OpenAlex
W2086735111
Cited by
34
References
3
FWCI
5.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.