Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 373

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Negative Stiffness Device for Seismic Protection of Structures

Sarlis, A. A., Pasala, D. T. R., Constantinou, M. C., Reinhorn, A. M., Nagarajaiah, S., Taylor, D. P. · 2013 · Journal of Structural Engineering

Abstract

Structural weakening and addition of damping is an approach previously proposed for the reduction of seismic forces and drifts in the retrofit of structures. It is also used in the design of new buildings with damping systems. While this approach is efficient, it does not significantly reduce and may even amplify inelastic excursions and permanent deformations of the structural system during a seismic event. This paper describes a negative stiffness device (NSD) that can emulate weakening of the structural system without inelastic excursions and permanent deformations. The NSD simulates yielding by engaging at a prescribed displacement and by applying a force at its installation level that opposes the structural restoring force. The NSD consists of (a) a self-contained highly compressed spring in a double negative stiffness magnification mechanism; and (b) a gap spring assembly (GSA) mechanism which delays the engagement of negative stiffness until the structural system undergoes a prescribed displacement. The NSD employs double chevron braces that self-contain the large vertical forces needed for the development of the horizontal negative stiffness without transferring these forces to the structure. This paper reports the development and operation of the NSD and presents analytical and computational tools that describe the behavior of the device. The principles of global control of structures using the NSD are presented in a companion paper. Additional papers present the results of testing of the device, and the results of analytical and experimental studies on the application of the device in a three-story conventional structure and a three-story seismically isolated structure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1061/(asce)st.1943-541x.0000616

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 373

Metadata

Authors
Sarlis, A. A., Pasala, D. T. R., Constantinou, M. C., Reinhorn, A. M., Nagarajaiah, S., & Taylor, D. P.
Venue
Journal of Structural Engineering
Published
2013-07
Volume
139
Issue
7
Pages
1124-1133
ISSN
  • 0733-9445 (ISSN-L)
  • 1943-541X
OpenAlex
W2035987497
Cited by
373
References
10
FWCI
23.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Negative Stiffness Device for Seismic Protection of Structures. https://app.cochat.ai/papers/10.1061/(asce)st.1943-541x.0000616
The paper
Sarlis, A. A., Pasala, D. T. R., Constantinou, M. C., Reinhorn, A. M., Nagarajaiah, S., & Taylor, D. P. (2013). Negative Stiffness Device for Seismic Protection of Structures. Journal of Structural Engineering. https://doi.org/10.1061/(asce)st.1943-541x.0000616

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.