The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Negative Stiffness Device for Seismic Protection of Structures
Abstract
Structural weakening and addition of damping is an approach previously proposed for the reduction of seismic forces and drifts in the retrofit of structures. It is also used in the design of new buildings with damping systems. While this approach is efficient, it does not significantly reduce and may even amplify inelastic excursions and permanent deformations of the structural system during a seismic event. This paper describes a negative stiffness device (NSD) that can emulate weakening of the structural system without inelastic excursions and permanent deformations. The NSD simulates yielding by engaging at a prescribed displacement and by applying a force at its installation level that opposes the structural restoring force. The NSD consists of (a) a self-contained highly compressed spring in a double negative stiffness magnification mechanism; and (b) a gap spring assembly (GSA) mechanism which delays the engagement of negative stiffness until the structural system undergoes a prescribed displacement. The NSD employs double chevron braces that self-contain the large vertical forces needed for the development of the horizontal negative stiffness without transferring these forces to the structure. This paper reports the development and operation of the NSD and presents analytical and computational tools that describe the behavior of the device. The principles of global control of structures using the NSD are presented in a companion paper. Additional papers present the results of testing of the device, and the results of analytical and experimental studies on the application of the device in a three-story conventional structure and a three-story seismically isolated structure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Minimum Design Loads for Buildings and Other Structures
American Society of Civil Engineers (2003) · American Society of Civil Engineers eBooks · doi:10.1061/9780784406243 · Cited by 3,879
Minimum Design Loads for Buildings and Other Structures
Cohen, E. (1990) · Cited by 1,356
Adaptive Negative Stiffness: New Structural Modification Approach for Seismic Protection
Pasala, D. T. R., Sarlis, A. A., Nagarajaiah, S., Reinhorn, A. M., Constantinou, M. C., & Taylor, D. (2013) · Journal of Structural Engineering · doi:10.1061/(asce)st.1943-541x.0000615 · Cited by 284
Self-citationDesign of springs with “negative” stiffness to improve vehicle driver vibration isolation
Lee, C.-M., Goverdovskiy, V. N., & Temnikov, A. I. (2007) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2006.12.024 · Cited by 171
Advances in the development of pseudo-negative-stiffness dampers for seismic response control
Iemura, H., & Pradono, M. H. (2009) · Structural Control and Health Monitoring · doi:10.1002/stc.345 · Cited by 160
Retrofit of a hospital through strength reduction and enhanced damping
Viti, S., Cimellaro, G. P., & Reinhorn, A. M. (2006) · Smart Structures and Systems · doi:10.12989/sss.2006.2.4.339 · Cited by 101
Self-citationResponse of Nonstructural Components in Structures with Damping Systems
Pavlou, E. A., & Constantinou, M. C. (2006) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(2006)132:7(1108 · Cited by 74
Self-citationSupports for vibration isolation
Molyneux, W. G. (1957) · Cited by 68
Retrofit of Structures: Strength Reduction with Damping Enhancement
Reinhorn, A. M., Viti, S., & Cimellaro, G. P. (2005) · PORTO Publications Open Repository TOrino (Politecnico di Torino) · Cited by 42
Self-citationPasala, D. T. R., Sarlis, A. A., Nagarajaiah, S., Reinhorn, A. M., Constantinou, M. C., & Taylor, D. (2011) · ASCE Structures Congress · doi:10.1061/41171(401)251 · Cited by 17
Self-citation
Cited by
Zadpoor, A. A. (2016) · Materials Horizons · doi:10.1039/c6mh00065g · Cited by 492
Mechanical metamaterials: a state of the art
Barchiesi, E., Spagnuolo, M., & Placidi, L. (2019) · Mathematics and Mechanics of Solids · doi:10.1177/1081286517735695 · Cited by 433
Buckling-induced smart applications: recent advances and trends
Hu, N., & Burgueño, R. (2015) · Smart Materials and Structures · doi:10.1088/0964-1726/24/6/063001 · Cited by 351
Lai, Z., & Nagarajaiah, S. (2019) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2018.08.033 · Cited by 134
Self-citationAttary, N., Symans, M., Nagarajaiah, S., Reinhorn, A. M., Constantinou, M. C., Sarlis, A. A., Pasala, D. T. R., & Taylor, D. (2015) · Journal of Earthquake Engineering · doi:10.1080/13632469.2014.962672 · Cited by 82
Self-citation
Metadata
- Authors
- Sarlis, A. A., Pasala, D. T. R., Constantinou, M. C., Reinhorn, A. M., Nagarajaiah, S., & Taylor, D. P.
- Venue
- Journal of Structural Engineering
- Published
- 2013-07
- Volume
- 139
- Issue
- 7
- Pages
- 1124-1133
- ISSN
- 0733-9445 (ISSN-L)
- 1943-541X
- OpenAlex
- W2035987497
- Cited by
- 373
- References
- 10
- FWCI
- 23.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Negative Stiffness Device for Seismic Protection of Structures. https://app.cochat.ai/papers/10.1061/(asce)st.1943-541x.0000616
- The paper
- Sarlis, A. A., Pasala, D. T. R., Constantinou, M. C., Reinhorn, A. M., Nagarajaiah, S., & Taylor, D. P. (2013). Negative Stiffness Device for Seismic Protection of Structures. Journal of Structural Engineering. https://doi.org/10.1061/(asce)st.1943-541x.0000616
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.