The DOI matches its Crossref record.
Data smoothing using low-pass digital filters
Abstract
With the increasing use of computer-controlled data acquisition systems which record data in digital form, there has developed a need for techniques which perform a general smoothing process on digitized experimental data. This processing enables the experimentalist to eliminate or greatly reduce the amount of high-frequency noise in order to obtain as accurate and clean representation of the true phenomenon as is consistent with his measurement accuracies. This filtering or smoothing process should be as simple and efficient (least amount of arithmetic per data sample) as is consistent with the experimental situation. The basic concepts of low-pass filters are discussed and four different low-pass filter design procedures are described, each with its own particular smoothing properties. These design procedures give directly the coefficients of a symmetrical weighting sequence having the desired passband width and the desired high-frequency noise rejection. The uses of the filters are illustrated with examples and the fortran code for implementing each of the design procedures is given in an Appendix.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 5
- 1967, Numer. Math., 10, 177, 10.1007/BF02162161 · DOI · Paper page
- 1975, Rev. Sci. Instrum., 46, 1414, 10.1063/1.1134076 · DOI
- 1971, IEEE Trans. Circuit Theory, CT-18, 411
- 1969, Nucl. Instrum. Methods, 67, 125, 10.1016/0029-554X(69)90551-5 · DOI
- 1972, IEEE Trans. Audio Electroacoustics, AU-20, 322
Cited by
Optimality in human motor performance: Ideal control of rapid aimed movements.
Meyer, D. E., Abrams, R. A., Kornblum, S., Wright, C. E., & Keith Smith, J. E. (1988) · Psychological Review · doi:10.1037/0033-295x.95.3.340 · Cited by 1,406
Effects of Sodium Ions on DNA Duplex Oligomers: Improved Predictions of Melting Temperatures
Owczarzy, R., You, Y., Moreira, B. G., Manthey, J. A., Huang, L., Behlke, M. A., & Walder, J. A. (2004) · Biochemistry · doi:10.1021/bi034621r · Cited by 332
Age-Related Differences in Movement Control: Adjusting Submovement Structure To Optimize Performance
Walker, N., Philbin, D. A., & Fisk, A. D. (1997) · The Journals of Gerontology Series B: Psychological Sciences and Social Sciences · doi:10.1093/geronb/52b.1.p40 · Cited by 262
Binomial smoothing filter: A way to avoid some pitfalls of least-squares polynomial smoothing
Marchand, P., & Marmet, L. (1983) · Review of Scientific Instruments · doi:10.1063/1.1137498 · Cited by 261
Abrams, R. A., Meyer, D. E., & Kornblum, S. (1989) · Journal of Experimental Psychology Human Perception & Performance · doi:10.1037//0096-1523.15.3.529 · Cited by 260
Metadata
- Authors
- Kaiser, J. F., & Reed, W. A.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1977-11-01
- Volume
- 48
- Issue
- 11
- Pages
- 1447-1457
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W1970239009
- Cited by
- 215
- References
- 0
- FWCI
- 3.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Data smoothing using low-pass digital filters. https://app.cochat.ai/papers/10.1063/1.1134918
- The paper
- Kaiser, J. F., & Reed, W. A. (1977). Data smoothing using low-pass digital filters. Review of Scientific Instruments. https://doi.org/10.1063/1.1134918
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.