The DOI matches its Crossref record.
Fast-response dual-beam UV-absorption ozone photometer suitable for use on stratospheric balloons
Abstract
Various types of ozone detectors are currently in use, each with different advantages and compromises in response time, portability, sensitivity, accuracy, need for repeated calibration, and expense. We describe here a new dual-beam UV-absorption instrument for balloon-borne measurements of atmospheric ozone. It has two identical absorption chambers, each alternating between reference mode (ozone free) and sample mode by means of a four-port valve and ozone scrubber. The ratio of the absorption signals, along with the known lengths and ozone absorption cross section, yield the ozone concentration. The dual-beam feature cancels the effects of lamp intensity fluctuations, while the mode alternation compensates for mechanical changes and also provides continuous measurements. The absorption measurement requires no calibration and, hence, is independent of gas flow rate. The response time is 1 s and, for this measurement duration, the minimum ozone concentration detectable by this instrument (one standard deviation) is 1.5×1010 molecules/cm3 (0.6 ppbv at STP). The overall uncertainty of a 1-s measurement at the ozone maximum (22 km) is 3.6%, where 2% of this is the accuracy of the ozone cross section. The size and weight are suitable for launch by small balloons, but the cost of the instrument precludes its use as a disposable unit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Schwarz, J. P., Gao, R. S., Fahey, D. W., Thomson, D. S., Watts, L. A., Wilson, J. C., Reeves, J. M., Darbeheshti, M., Baumgardner, D. G., Kok, G. L., et al. (2006) · Journal of Geophysical Research: Atmospheres · doi:10.1029/2006jd007076 · Cited by 772
Increasing springtime ozone mixing ratios in the free troposphere over western North America
Cooper, O. R., Parrish, D. D., Stohl, A., Trainer, M., Nédélec, P., Thouret, V., Cammas, J. P., Oltmans, S. J., Johnson, B. J., Tarasick, D., et al. (2010) · Nature · doi:10.1038/nature08708 · Cited by 403
Smit, H. G. J., Straeter, W., Johnson, B. J., Oltmans, S. J., Davies, J., Tarasick, D. W., Hoegger, B., Stubi, R., Schmidlin, F. J., Northam, T., et al. (2007) · Journal of Geophysical Research: Atmospheres · doi:10.1029/2006jd007308 · Cited by 400
A tropical West Pacific OH minimum and implications for stratospheric composition
Rex, M., Wohltmann, I., Ridder, T., Lehmann, R., Rosenlof, K., Wennberg, P., Weisenstein, D., Notholt, J., Krüger, K., Mohr, V., et al. (2014) · Atmospheric Chemistry and Physics · doi:10.5194/acp-14-4827-2014 · Cited by 79
Metadata
- Authors
- Proffitt, M. H., & McLaughlin, R. J.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1983-12-01
- Volume
- 54
- Issue
- 12
- Pages
- 1719-1728
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2050531997
- Cited by
- 185
- References
- 0
- FWCI
- 2.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fast-response dual-beam UV-absorption ozone photometer suitable for use on stratospheric balloons. https://app.cochat.ai/papers/10.1063/1.1137316
- The paper
- Proffitt, M. H., & McLaughlin, R. J. (1983). Fast-response dual-beam UV-absorption ozone photometer suitable for use on stratospheric balloons. Review of Scientific Instruments. https://doi.org/10.1063/1.1137316
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.