Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 185

The DOI matches its Crossref record.

Fast-response dual-beam UV-absorption ozone photometer suitable for use on stratospheric balloons

Proffitt, Michael H., McLaughlin, Richard J.·1983·Review of Scientific Instruments

Abstract

Various types of ozone detectors are currently in use, each with different advantages and compromises in response time, portability, sensitivity, accuracy, need for repeated calibration, and expense. We describe here a new dual-beam UV-absorption instrument for balloon-borne measurements of atmospheric ozone. It has two identical absorption chambers, each alternating between reference mode (ozone free) and sample mode by means of a four-port valve and ozone scrubber. The ratio of the absorption signals, along with the known lengths and ozone absorption cross section, yield the ozone concentration. The dual-beam feature cancels the effects of lamp intensity fluctuations, while the mode alternation compensates for mechanical changes and also provides continuous measurements. The absorption measurement requires no calibration and, hence, is independent of gas flow rate. The response time is 1 s and, for this measurement duration, the minimum ozone concentration detectable by this instrument (one standard deviation) is 1.5×1010 molecules/cm3 (0.6 ppbv at STP). The overall uncertainty of a 1-s measurement at the ozone maximum (22 km) is 3.6%, where 2% of this is the accuracy of the ozone cross section. The size and weight are suitable for launch by small balloons, but the cost of the instrument precludes its use as a disposable unit.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.1137316

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 185

Metadata

Authors
Proffitt, M. H., & McLaughlin, R. J.
Venue
Review of Scientific Instruments
Published
1983-12-01
Volume
54
Issue
12
Pages
1719-1728
ISSN
  • 0034-6748 (ISSN-L)
  • 1089-7623
OpenAlex
W2050531997
Cited by
185
References
0
FWCI
2.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fast-response dual-beam UV-absorption ozone photometer suitable for use on stratospheric balloons. https://app.cochat.ai/papers/10.1063/1.1137316
The paper
Proffitt, M. H., & McLaughlin, R. J. (1983). Fast-response dual-beam UV-absorption ozone photometer suitable for use on stratospheric balloons. Review of Scientific Instruments. https://doi.org/10.1063/1.1137316

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.