The DOI matches its Crossref record.
2-GHz frequency-domain fluorometer
Abstract
We developed a frequency-domain fluorometer which operates from 4 to 2000 MHz. The modulated excitation is provided by the harmonic content of a laser pulse train (3.76 MHz, 5 ps) from a synchronously pumped and cavity dumped dye laser. The phase angle and modulation of the emission are measured with a microchannel-plate photomultiplier (PMT). Cross-correlation detection is performed outside the PMT. The high-frequency signals for cross correlation were obtained by multiplication of the output from a 500-MHz frequency synthesizer. The performance was verified in several ways, including measurement of known time delays and examination of standard fluorophores. The detector displayed no detectable color effect, with the 300–600-nm difference being less than 5 ps. The precision of the measurements is adequate to detect differences of 20 ps for decay times of 500 ps. A correlation time of 53 ps was found for indole in water at 20 °C. The shortest correlation time we measured was 15 ps for indole in methanol/water (75/25) at 40 °C. Also, the 2-GHz data reveal the time-dependent ((t)1/2) terms found in the presence of collisional quenching. The degree of random error is about 0.3° of phase and 0.005 in modulation throughout the frequency range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Quantification in tissue near–infrared spectroscopy
Delpy, D. T., & Cope, M. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0046 · Cited by 507
Fluorescence Techniques for Studying Protein Structure
Eftink, M. R. (1991) · Methods of Biochemical Analysis · doi:10.1002/9780470110560.ch3 · Cited by 504
Lakowicz, J. R., Szmacinski, H., Nowaczyk, K., Berndt, K. W., & Johnson, M. (1992) · Analytical Biochemistry · doi:10.1016/0003-2697(92)90112-k · Cited by 446
Self-citationIn Vivo Near-Infrared Spectroscopy
Rolfe, P. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.715 · Cited by 273
[13] Maximum entropy method of data analysis in time-resolved spectroscopy
Brochon, J.-C. (1994) · Methods in Enzymology · doi:10.1016/s0076-6879(94)40052-0 · Cited by 257
Metadata
- Authors
- Lakowicz, J. R., Laczko, G., & Gryczynski, I.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1986-10-01
- Volume
- 57
- Issue
- 10
- Pages
- 2499-2506
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2091814497
- Cited by
- 213
- References
- 0
- FWCI
- 21.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 2-GHz frequency-domain fluorometer. https://app.cochat.ai/papers/10.1063/1.1139215
- The paper
- Lakowicz, J. R., Laczko, G., & Gryczynski, I. (1986). 2-GHz frequency-domain fluorometer. Review of Scientific Instruments. https://doi.org/10.1063/1.1139215
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.