Automatic rotating element ellipsometers: Calibration, operation, and real-time applications

Collins, R. W.·1990·Review of Scientific Instruments

Abstract

In a typical reflection ellipsometry experiment, one characterizes the polarization state change that a polarized light beam undergoes upon reflection from a specular surface. This measurement provides ρ≡rp/rs, where rp and rs are the complex amplitude reflection coefficients of the surface for p- and s-polarized waves. Nearly 15 years have passed since the development of automatic ellipsometers along with the detailed calibration, error analysis, and data reduction procedures to be used with them. More specifically, these powerful instruments permit (1) determination of bulk dielectric functions and nondestructive depth profiling of static multilayered materials through measurements as a function of photon energy and (2) characterization of dynamic surfaces in adverse environments through measurements as a function of time at fixed photon energy. In the 15 intervening years, the major research thrusts in ellipsometry have been the exploitation of these instruments in materials and process characterization in diverse areas of materials science and electrochemistry. One of the simplest and most popular automatic ellipsometers is a photometric instrument in which one or more of the optical elements (polarizer, compensator, and/or analyzer) is designed to rotate continuously. In this article, the major developments in rotating element ellipsometry are reviewed since the first report of an automatic rotating analyzer instrument by Cahan and Spanier in 1969. The topics covered include rotating element configurations, calibration, characterization of errors and imperfections, absolute accuracy, data reduction, precision, and a review of the real-time applications accessible to these instruments. The sections on calibration, errors, and data reduction include new material and are written from a practical standpoint to assist in instrumentation setup and troubleshooting. The development and improvement of next-generation rotating element instruments that employ optical multichannel detectors to collect spectroscopic data on dynamic surfaces with time resolution as short as 5 ms now defines the forefront of research in this field.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.1141417

Cites

52 of 52 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 52 references

Cited by

Metadata

Authors
Collins, R. W.
Venue
Review of Scientific Instruments
Published
1990-08-01
Volume
61
Issue
8
Pages
2029-2062
ISSN
  • 0034-6748 (ISSN-L)
  • 1089-7623
OpenAlex
W1993621873
Cited by
282
References
52
FWCI
17.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automatic rotating element ellipsometers: Calibration, operation, and real-time applications. https://app.cochat.ai/papers/10.1063/1.1141417
The paper
Collins, R. W. (1990). Automatic rotating element ellipsometers: Calibration, operation, and real-time applications. Review of Scientific Instruments. https://doi.org/10.1063/1.1141417

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.