Cited by 385Thermal properties of materialsThermography and Photoacoustic TechniquesHeat Transfer and Numerical Methods

Thermal conductivity, thermal diffusivity, and specific heat of thin samples from transient measurements with hot disk sensors

Gustavsson, Mattias, Karawacki, Ernest, Gustafsson, Silas E.·1994·Review of Scientific Instruments

Abstract

Transient measurements of thermal conductivity, thermal diffusivity, and specific heat capacity have been performed with hot disk sensors in thin samples of metallic materials. With this new variation of the hot disk method the sample size can be reduced to a volume less than ten cubic centimeters for copper at room temperature. It is also shown that the specific heat capacity can be conveniently measured in transient recordings of slightly longer duration. On comparing with standard values the accuracy turns out to be better than 1% while the precision (standard deviation of the mean from six measurements) on the average is about 0.5% for all values recorded.

Integrity signals

Registry

Crossref · 10.1063/1.1145178

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • TPS methods can be extended to study slab materials, thin film specimens (dimensions < d), and anisotropic materials, in addition to isotropic bulk materials and fluids.

    “In addition to isotropic bulk materials, 1, 10, 11 and fluid, 12, 13 the TPS methods can be extended to study slab materials, thin film specimens (dimensions &lt; d ) and anisotropic materials. 14”

Cited by

Sorted by citations

Authors
Gustavsson, M., Karawacki, E., & Gustafsson, S. E.
Affiliations
Chalmers University of Technology (SE)
Venue
Review of Scientific Instruments
Published
1994-12-01
Volume
65
Issue
12
Pages
3856-3859
ISSN
  • 0034-6748 (ISSN-L)
  • 1089-7623
OpenAlex
W1967668987
Cited by
385
References
0
Citations by year
2026: 21 · 2025: 14 · 2024: 19 · 2023: 17 · 2022: 25 · 2021: 26 · 2020: 27 · 2019: 29 · 2018: 18 · 2017: 23 · 2016: 22 · 2015: 19 · 2014: 19 · 2013: 16 · 2012: 12
FWCI
0.00
Type
journal article
Language
en
Open access
closed
Locations
Review of Scientific Instruments (publishedVersion)
Topics
  • Physical Sciences › Materials Science › Materials Chemistry › Thermal properties of materials
  • Physical Sciences › Engineering › Mechanics of Materials › Thermography and Photoacoustic Techniques
  • Physical Sciences › Engineering › Computational Mechanics › Heat Transfer and Numerical Methods
Keywords
thermal conductivity, thermal diffusivity, specific heat, hot disk method, transient thermal measurement, thin samples, copper, metals, precision and accuracy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review