The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Measurement of heat capacity by fitting the whole temperature response of a heat-pulse calorimeter
Abstract
A new method that fits the whole temperature response of a heat-pulse calorimeter for heat capacity is developed. Analyzing the thermal response of a heat-pulse calorimeter on a model that was used by the relaxation method, the authors derived some useful relations and further utilized the numeric method of the general linear least squares to determine the heat capacity of a sample. Absolute accuracy of the proposed method was verified by determining the heat capacity of a 0.249 76 g copper sample (purity 99.999%) on a self-designed and fully automated calorimetric system from 4.5 to 80 K. Comparing the result with the literature, the deviation in average was 1.2% from 4.5 to 20 K and 2.0% from 20 to 80 K. It is found that the proposed method is capable of measuring heat capacity regardless if the sample is adiabatically or nonadiabatically isolated. The size of the specimen is not critical for the application of the method and the temperature range of measurement can be expanded. It also deals with the τ2 effect. Details of the employed calorimetric system are described. Stability, inherent limitations, and further improvement of the system are also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Steady-State, ac-Temperature Calorimetry
Sullivan, P. F., & Seidel, G. (1968) · Physical Review · doi:10.1103/physrev.173.679 · Cited by 750
Heat Capacity Measurements on Small Samples at Low Temperatures
Bachmann, R., DiSalvo, F. J., Geballe, T. H., Greene, R. L., Howard, R. E., King, C. N., Kirsch, H. C., Lee, K. N., Schwall, R. E., Thomas, H.-U., et al. (1972) · Review of Scientific Instruments · doi:10.1063/1.1685596 · Cited by 556
Measurement of low-temperature specific heat
Stewart, G. R. (1983) · Review of Scientific Instruments · doi:10.1063/1.1137207 · Cited by 422
Osborne, D. W., Flotow, H. E., & Schreiner, F. (1967) · Review of Scientific Instruments · doi:10.1063/1.1771348 · Cited by 218
Modern low-temperature calorimetry
Gmelin, E. (1979) · Thermochimica Acta · doi:10.1016/0040-6031(79)85018-2 · Cited by 122
A dual-slope method for specific heat measurements
Riegel, S., & Weber, G. (1986) · Journal of Physics E Scientific Instruments · doi:10.1088/0022-3735/19/10/006 · Cited by 73
Martin, D. L. (1987) · Review of Scientific Instruments · doi:10.1063/1.1139230 · Cited by 71
Specific heat of GE 7031 varnish (4 – 18 K)
Cude, J. L., & Finegold, L. X. (1971) · Cryogenics · doi:10.1016/0011-2275(71)90039-7 · Cited by 28
Cited by
Measuring thermoelectric transport properties of materials
Borup, K. A., de Boor, J., Wang, H., Drymiotis, F., Gascoin, F., Shi, X., Chen, L., Fedorov, M. I., Müller, E., Iversen, B. B., et al. (2015) · Energy & Environmental Science · doi:10.1039/c4ee01320d · Cited by 380
Kim, H. J., Kim, U., Kim, T. H., Kim, J., Kim, H. M., Jeon, B.-G., Lee, W.-J., Mun, H. S., Hong, K. T., Yu, J., et al. (2012) · Physical Review B · doi:10.1103/physrevb.86.165205 · Cited by 320
Magnetothermal properties of molecule-based materials
Evangelisti, M., Luis, F., de Jongh, L. J., & Affronte, M. (2006) · Journal of Materials Chemistry · doi:10.1039/b603738k · Cited by 315
Demkó, L., Kézsmárki, I., Csontos, M., Bordács, S., & Mihály, G. (2010) · The European Physical Journal B · doi:10.1140/epjb/e2010-00055-0 · Cited by 7
Low Temperature Thermal Properties of Nanodiamond Ceramics
Szewczyk, D., & Ramos, M. A. (2022) · Crystals · doi:10.3390/cryst12121774 · Cited by 6
Metadata
- Authors
- Hwang, J. S., Lin, K. J., & Tien, C.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1997-01-01
- Volume
- 68
- Issue
- 1
- Pages
- 94-101
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2047900559
- Cited by
- 264
- References
- 8
- FWCI
- 2.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.