The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Photodetachment photoelectron spectroscopy of multiply charged anions using electrospray ionization
Abstract
A magnetic-bottle time-of-flight (TOF) photoelectron spectrometer, coupled with an electrospray ionization source, has been developed for the investigation of multiply charged anions in the gas phase. Anions formed in the electrospray source are guided by a radio-frequency quadrupole ion guide into a quadrupole ion trap, where the ions are accumulated. A unique feature of this apparatus involves the coupling of a TOF mass spectrometer to the ion trap with perpendicular ion extraction. The ion trap significantly improves the duty cycle of the experiments and allows photodetachment experiments to be performed with low repetition-rate lasers (10–20 Hz). This novel combination makes the photodetachment photoelectron spectroscopy studies of multiply charged anions possible for the first time. Furthermore, the perpendicular extraction of ions, pulsed out of the ion trap, to the TOF mass spectrometer allows the ion energies to be conveniently referenced to ground, simplifying the configuration of the TOF mass spectrometer and the subsequent magnetic-bottle TOF photoelectron spectrometer. The mass resolution (M/ΔM) achieved is about 800 for smaller ions. The magnetic-bottle photoelectron spectrometer resolution is about 11 meV full width at half maximum for 0.5 eV photoelectrons with an overall resolution of ΔE/E∼2%. The detailed design, construction, and operation of the new apparatus are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Cited by
Li, J., Li, X., Zhai, H.-J., & Wang, L.-S. (2003) · Science · doi:10.1126/science.1079879 · Cited by 1,185
Self-citationFemtosecond Time-Resolved Photoelectron Spectroscopy
Stolow, A., Bragg, A. E., & Neumark, D. M. (2004) · Chemical Reviews · doi:10.1021/cr020683w · Cited by 701
Synthesis of the H-cluster framework of iron-only hydrogenase
Tard, C., Liu, X., Ibrahim, S. K., Bruschi, M., Gioia, L. D., Davies, S. C., Yang, X., Wang, L.-S., Sawers, G., & Pickett, C. J. (2005) · Nature · doi:10.1038/nature03298 · Cited by 508
Self-citationAlexandrova, A. N., Boldyrev, A. I., Fu, Y.-J., Yang, X., Wang, X.-B., & Wang, L.-S. (2004) · The Journal of Chemical Physics · doi:10.1063/1.1783276 · Cited by 271
Self-citationFrontiers in the spectroscopy of mass-selected molecular ions
Duncan, M. A. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00366-3 · Cited by 270
Metadata
- Authors
- Wang, L.-S., Ding, C.-F., Wang, X.-B., & Barlow, S. E.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1999-04-01
- Volume
- 70
- Issue
- 4
- Pages
- 1957-1966
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2094550967
- Cited by
- 225
- References
- 1
- FWCI
- 10.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Photodetachment photoelectron spectroscopy of multiply charged anions using electrospray ionization. https://app.cochat.ai/papers/10.1063/1.1149694
- The paper
- Wang, L.-S., Ding, C.-F., Wang, X.-B., & Barlow, S. E. (1999). Photodetachment photoelectron spectroscopy of multiply charged anions using electrospray ionization. Review of Scientific Instruments. https://doi.org/10.1063/1.1149694
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.