The DOI matches its Crossref record.
Nonlinear scanning laser microscopy by third harmonic generation
Abstract
Third harmonic generation near the focal point of a tightly focused beam is used to probe microscopical structures of transparent samples. It is shown that this method can resolve interfaces and inhomogeneities with axial resolution comparable to the confocal length of the beam. Using 120 fs pulses at 1.5 μm, we were able to resolve interfaces with a resolution of 1.2 μm. Two-dimensional cross-sectional images have also been produced.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
In vivo three-photon microscopy of subcortical structures within an intact mouse brain
Horton, N. G., Wang, K., Kobat, D., Clark, C. G., Wise, F. W., Schaffer, C. B., & Xu, C. (2013) · Nature Photonics · doi:10.1038/nphoton.2012.336 · Cited by 1,505
Coherent Anti-Stokes Raman Scattering Microscopy: Instrumentation, Theory, and Applications
Cheng, J.-X., & Xie, X. S. (2004) · The Journal of Physical Chemistry B · doi:10.1021/jp035693v · Cited by 963
Laser-Scanning Coherent Anti-Stokes Raman Scattering Microscopy and Applications to Cell Biology
Cheng, J.-X., Jia, Y. K., Zheng, G., & Xie, X. S. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75186-2 · Cited by 371
Metadata
- Authors
- Barad, Y., Eisenberg, H., Horowitz, M., & Silberberg, Y.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1997-02-24
- Volume
- 70
- Issue
- 8
- Pages
- 922-924
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1965229287
- Cited by
- 607
- References
- 0
- FWCI
- 7.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nonlinear scanning laser microscopy by third harmonic generation. https://app.cochat.ai/papers/10.1063/1.118442
- The paper
- Barad, Y., Eisenberg, H., Horowitz, M., & Silberberg, Y. (1997). Nonlinear scanning laser microscopy by third harmonic generation. Applied Physics Letters. https://doi.org/10.1063/1.118442
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.