CoChat

Quantitative measurement of muscle hemoglobin oxygenation using near-infrared spectroscopy with correction for the influence of a subcutaneous fat layer

Niwayama, Masatsugu, Lin, Ling, Shao, Jun, Kudo, Nobuki, Yamamoto, Katsuyuki · 2000 · Review of Scientific Instruments
Cited by 94

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The inhomogeneity of tissue structure greatly affects the sensitivity of tissue oxygenation measurement by reflectance near-infrared spectroscopy. In this study, we investigated the influence of a fat layer on muscle oxygenation measurement by in vivo tests and Monte Carlo simulation, and we propose a method for correcting the influence. In the simulation, a three-dimensional model consisting of the epidermis, dermis, fat, and muscle layers was used. In in vivo tests, measurement sensitivity was examined by measuring oxygen consumption of the forearm muscle and the peak-to-peak variation of oxygenation in periodic exercise tests on the vastus lateralis using a newly developed multisensor type of tissue oximeter. Fat layer thickness was also measured by ultrasonography. The correction curve of measurement sensitivity against fat layer thickness was obtained from the results of simulation and in vivo tests. The values of corrected oxygen consumption were almost the same and had less variation between individuals (0.13±0.02 ml 100 g−1 min−1) than did the uncorrected values (0.08±0.04 ml 100 g−1 min−1).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.1322578

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Niwayama, M., Lin, L., Shao, J., Kudo, N., & Yamamoto, K.
Venue
Review of Scientific Instruments
Published
2000-12-01
Volume
71
Issue
12
Pages
4571-4575
ISSN
  • 0034-6748 (ISSN-L)
  • 1089-7623
OpenAlex
W2047301560
Cited by
94
References
2
FWCI
3.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.