The DOI matches its Crossref record.
Resolution limits for infrared microspectroscopy explored with synchrotron radiation
Abstract
The spatial resolution for infrared microspectroscopy is investigated to determine the practical limits imposed by diffraction or optical aberrations. Quantitative results are obtained using high brightness synchrotron radiation, which serves as a diffraction-limited infrared “point source” for the microscope. The measured resolving power is in good agreement with diffraction theory, including a ∼ 30% improvement for a confocal optical arrangement. The diffraction calculation also shows how the confocal setup leads to better image contrast. The full width at half maximum of the instrument’s resolution pattern is approximately λ/2 for this arrangement. One achieves this diffraction limit when the instrument’s apertures define a region having dimensions equal to the wavelength of interest. While commercial microspectrometers are well corrected for optical aberrations (allowing diffraction-limited results), the standard substrates used for supporting specimens introduce chromatic aberrations. An analysis of this aberration is also presented, and correction methods described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Yee, N., Benning, L. G., Phoenix, V. R., & Ferris, F. G. (2004) · Environmental Science & Technology · doi:10.1021/es0346680 · Cited by 403
Spectral pre-processing for biomedical vibrational spectroscopy and microspectroscopic imaging
Lasch, P. (2012) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2012.03.011 · Cited by 353
High-resolution Fourier-transform infrared chemical imaging with multiple synchrotron beams
Nasse, M. J., Walsh, M. J., Mattson, E. C., Reininger, R., Kajdacsy-Balla, A., Macias, V., Bhargava, R., & Hirschmugl, C. J. (2011) · Nature Methods · doi:10.1038/nmeth.1585 · Cited by 349
Levin, I. W., & Bhargava, R. (2005) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.56.092503.141205 · Cited by 300
Theory of Midinfrared Absorption Microspectroscopy: I. Homogeneous Samples
Davis, B. J., Carney, P. S., & Bhargava, R. (2010) · Analytical Chemistry · doi:10.1021/ac902067p · Cited by 115
Metadata
- Authors
- Carr, G. L.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2001-03-01
- Volume
- 72
- Issue
- 3
- Pages
- 1613-1619
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2008071996
- Cited by
- 220
- References
- 0
- FWCI
- 6.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Resolution limits for infrared microspectroscopy explored with synchrotron radiation. https://app.cochat.ai/papers/10.1063/1.1347965
- The paper
- Carr, G. L. (2001). Resolution limits for infrared microspectroscopy explored with synchrotron radiation. Review of Scientific Instruments. https://doi.org/10.1063/1.1347965
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.