Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 262

The DOI matches its Crossref record.

Responsive biomimetic hydrogel valve for microfluidics

Yu, Qing, Bauer, Joseph M., Moore, Jeffrey S., Beebe, David J.·2001·Applied Physics Letters

Abstract

A biomimetic hydrogel valve capable of directional flow control in response to the local fluid environment in microfluidic channels is described. The valve consists of a pair of photopolymerized hydrogel bistrips with different pH sensitivities, and becomes activated or deactivated reversibly based on local pH as a result of volume and shape changes. When activated at pH 8, the valve mimics anatomic venous valves both functionally and structurally, allowing fluid flow in one direction under forward pressure while restricting flow in the opposite direction. At an applied pressure of 0.71 psi, the forward flow rate was 140 μL/min, compared to a backward leakage rate of 2.3 μL/min.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.1367010

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 262

Metadata

Authors
Yu, Q., Bauer, J. M., Moore, J. S., & Beebe, D. J.
Venue
Applied Physics Letters
Published
2001-04-23
Volume
78
Issue
17
Pages
2589-2591
ISSN
  • 0003-6951 (ISSN-L)
  • 1077-3118
OpenAlex
W1985718165
Cited by
262
References
0
FWCI
6.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Responsive biomimetic hydrogel valve for microfluidics. https://app.cochat.ai/papers/10.1063/1.1367010
The paper
Yu, Q., Bauer, J. M., Moore, J. S., & Beebe, D. J. (2001). Responsive biomimetic hydrogel valve for microfluidics. Applied Physics Letters. https://doi.org/10.1063/1.1367010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.