Langmuir probe analysis for high density plasmas
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
High-density, radio-frequency plasmas used in semiconductor processing have progressed to densities n⩾5×1011 cm−3, where the methods used to interpret Langmuir probe characteristics in low-density (109–11 cm−3) plasma reactors are no longer valid. Though theory and computations for arbitrarily dense collisionless plasmas exist, they are difficult to apply in real time. A new parametrization and iteration scheme is given which permits rapid analysis of Langmuir probe data using these theories. However, at high n, measured ion saturation curves are shown which do not agree in shape with the “correct” theory, yielding anomalously high values of n. The discrepancy with independent measures of n, which can exceed a factor of 2, is believed to be caused by charge-exchange collisions well outside the sheath. Probe designs for avoiding this discrepancy are suggested.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Plasma Discharges and Materials Processing
Lieberman, M. A., & Lichtenberg, A. J. (2005) · doi:10.1002/0471724254 · Cited by 4,748
Cited by
Godyak, V. A., Piejak, R. B., & Alexandrovich, B. M. (2002) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/11/4/320 · Cited by 378
Donnelly, V. M. (2004) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/37/19/r01 · Cited by 268
Metadata
- Authors
- Chen, F. F.
- Venue
- Physics of Plasmas
- Publisher
- AIP Publishing
- Published
- 2001-06-01
- Volume
- 8
- Issue
- 6
- Pages
- 3029-3041
- ISSN
- 1070-664X (ISSN-L)
- 1089-7674
- OpenAlex
- W2048861789
- Cited by
- 207
- References
- 1
- FWCI
- 7.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.