The DOI matches its Crossref record.
Quantitative modulated excitation Fourier transform infrared spectroscopy
Abstract
The detection of weak absorption changes induced by an external excitation is often hindered by intense background absorptions as well as by noise. Modulation spectroscopy is an adequate tool to be applied in such a case, provided the system may be periodically stimulated, leading to a periodic reversible or pseudoreversible response. In modulated excitation (ME) Fourier transform infrared spectroscopy the phase sensitive detection (PSD) used for the demodulation of the periodic system response is generally performed during data acquisition, i.e., applied to the intensity of the interferogram. This leads to a number of problems in quantitative analysis and the requirement of optional equipment. In this article, a method is presented to perform an off-line vector PSD of conventional time-resolved spectra after data acquisition. A detailed mathematical analysis of PSD applied to the spectral intensity, the interferogram intensity, and to time-resolved spectra is presented. It is shown, that vector PSD applied to a set of time-resolved spectra is straightforward and avoids any additional mathematical corrections. Furthermore, it will be shown how ME spectroscopy can be used for experimental separation of overlapping bands and a detailed description for the determination of absolute modulation amplitudes and phase lags is given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The concept of active site in heterogeneous catalysis
Vogt, C., & Weckhuysen, B. M. (2022) · Nature Reviews Chemistry · doi:10.1038/s41570-021-00340-y · Cited by 851
Hess, C. (2021) · Chemical Society Reviews · doi:10.1039/d0cs01059f · Cited by 344
Ebner, K., Clark, A. H., Saveleva, V. A., Smolentsev, G., Chen, J., Ni, L., Li, J., Zitolo, A., Jaouen, F., Kramm, U. I., et al. (2022) · Advanced Energy Materials · doi:10.1002/aenm.202103699 · Cited by 61
Metadata
- Authors
- Baurecht, D., & Fringeli, U. P.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2001-10-01
- Volume
- 72
- Issue
- 10
- Pages
- 3782-3792
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2029954800
- Cited by
- 236
- References
- 0
- FWCI
- 3.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative modulated excitation Fourier transform infrared spectroscopy. https://app.cochat.ai/papers/10.1063/1.1400152
- The paper
- Baurecht, D., & Fringeli, U. P. (2001). Quantitative modulated excitation Fourier transform infrared spectroscopy. Review of Scientific Instruments. https://doi.org/10.1063/1.1400152
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.