Simultaneous in situ detection of atmospheric NO3 and N2O5 via cavity ring-down spectroscopy
The DOI matches its Crossref record.
Abstract
This article describes the application of cavity ring-down spectroscopy (CaRDS) to the simultaneous concentration measurement of nitrate radical, NO3, and dinitrogen pentoxide, N2O5, in the ambient atmosphere. The sensitivity for detection of both NO3 and N2O5 is 0.5 pptv (2σ) for a 5 s integration, comparable to or better than previous measurements of NO3 (e.g., via DOAS), but with significantly better time resolution. Furthermore, direct measurement of N2O5 represent a previously unavailable capability. Concentrations of both species are measured simultaneously in two separate flow systems and optical cavities pumped by the same pulsed dye laser at 662 nm. One of the flow systems remains at ambient temperature for detection of NO3, while the other is heated to 80 °C to induce thermal decomposition of N2O5 providing a measurement of the sum of the NO3 and N2O5 concentrations. This article outlines a series of laboratory and field tests of the instrument’s performance. Important considerations include signal acquisition, zero measurements, aerosol interference, flow system losses, and the conversion efficiency for N2O5 thermolysis to NO3. We describe the limitations of this method and show how they can be quantified and accounted for in field measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nighttime radical observations and chemistry
Brown, S. S., & Stutz, J. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35181a · Cited by 637
Self-citationNitrate radicals and biogenic volatile organic compounds: oxidation, mechanisms, and organic aerosol
Ng, N. L., Brown, S. S., Archibald, A. T., Atlas, E., Cohen, R. C., Crowley, J. N., Day, D. A., Donahue, N. M., Fry, J. L., Fuchs, H., et al. (2017) · Atmospheric Chemistry and Physics · doi:10.5194/acp-17-2103-2017 · Cited by 595
Self-citationHeterogeneous Atmospheric Chemistry, Ambient Measurements, and Model Calculations of N2O5: A Review
Chang, W. L., Bhave, P. V., Brown, S. S., Riemer, N., Stutz, J., & Dabdub, D. (2011) · Aerosol Science and Technology · doi:10.1080/02786826.2010.551672 · Cited by 260
Self-citationKercher, J. P., Riedel, T. P., & Thornton, J. A. (2009) · Atmospheric Measurement Techniques · doi:10.5194/amt-2-193-2009 · Cited by 226
“Our goal was to provide high quality measurements of ClNO2 and to test the performance of our N2O5 measurement technique side-by-side with the NOAA CaRDS instrument (Brown et al., 2002).”
MethodHuey, L. G. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20118 · Cited by 189
The role of ice in N 2 O 5 heterogeneous hydrolysis at high latitudes
Apodaca, R. L., Huff, D. M., & Simpson, W. R. (2008) · Atmospheric Chemistry and Physics · doi:10.5194/acp-8-7451-2008 · Cited by 28
“…to detect NO3 and N2O5 have been developed to study this pathway (Platt et al., 1980; Geyer and Stutz, 2004; Stutz et al., 2004; King et al., 2000; Brown et al., 2001, 2002, 2003; Simpson, 2003; Wood et al., 2003; Ayers et al., 2005; Brown et al., 2006b; Published by Copernicus Publications on…”
BackgroundMeasurements of N2O5 near Fairbanks, Alaska
Ayers, J. D., & Simpson, W. R. (2006) · Journal of Geophysical Research: Atmospheres · doi:10.1029/2006jd007070 · Cited by 28
Deposition of dinitrogen pentoxide, N 2 O 5 , to the snowpack at high latitudes
Huff, D. M., Joyce, P. L., Fochesatto, G. J., & Simpson, W. R. (2011) · Atmospheric Chemistry and Physics · doi:10.5194/acp-11-4929-2011 · Cited by 27
Metadata
- Authors
- Brown, S. S., Stark, H., Ciciora, S. J., McLaughlin, R. J., & Ravishankara, A. R.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2002-09-01
- Volume
- 73
- Issue
- 9
- Pages
- 3291-3301
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W1888755143
- Cited by
- 142
- References
- 0
- FWCI
- 3.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.