Design of a triple resonance magic angle sample spinning probe for high field solid state nuclear magnetic resonance
The DOI matches its Crossref record.
Abstract
Standard design and construction practices used in building nuclear magnetic resonance (NMR) probes for the study of solid state samples become difficult if not entirely impractical to implement as the 1H resonance frequency approaches the self resonance frequency of commercial capacitors. We describe an approach that utilizes short variable transmission line segments as tunable reactances. Such an approach effectively controls stray reactances and provides a higher Q alternative to ceramic chip capacitors. The particular probe described is built to accommodate a 2.5 mm magic angle spinning rotor system, and is triply tuned to 13C, 15N, and 1H frequencies for use at 18.8 T (200, 80, and 800 MHz, respectively). Isolation of the three radio frequency (rf) channels is achieved using both a rejection trap and a transmission line notch filter. The compact geometry of this design allows three channels with high power handling capability to fit in a medium bore (63 mm) magnet. Extended time variable temperature operation is integral to the mechanical design, enabling the temperature control necessary for investigation of biological macromolecules. Accurate measurement of the air temperature near the sample rotor is achieved using a fiber optic thermometer, which does not interfere with the rf electronics. We also demonstrate that acceptable line shapes are only readily achieved using zero magnetic susceptibility wire in construction of the sample coil. Computer simulation of the circuit aided in the physical design of the probe. Representative data illustrating the efficiency, rf homogeneity, and signal to noise factor of the probe are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Solid-state NMR experiments in conductive and dielectrically lossy protein samples are hindered by significant sample heating from high-frequency irradiation during cross-polarization (CP) and decoupling pulses [1-3].”
From Using low-E resonators to reduce RF heating in biological samples for static solid-state NMR up to 900MHz (2007) · cites this paper as [1]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 18
- 1976, J. Am. Chem. Soc., 98, 1031, 10.1021/ja00420a036 · DOI · Paper page
- 1976, Rev. Sci. Instrum., 47, 1486, 10.1063/1.1134560 · DOI
- 1980, Rev. Sci. Instrum., 51, 887, 10.1063/1.1136352 · doi:10.1063/1.1136352
- 1998, Microwaves RF, 37, 15
- 1999, Microwave J., 42, 19
- 1999, Microwaves RF, 38, 109
- 2000, Microwave J., 43, 96
- 1987, IEEE Trans. Compon., Hybrids, Manuf. Technol., 10, 487, 10.1109/TCHMT.1987.1134797 · doi:10.1109/tchmt.1987.1134797
- 1997, IEEE Trans. Microwave Theory Tech., 45, 311, 10.1109/22.557620 · doi:10.1109/22.557620
- 2001, J. Phys. D, 34, 2875, 10.1088/0022-3727/34/18/322 · doi:10.1088/0022-3727/34/18/322
- 1981, J. Magn. Reson., 43, 399
- 1992, Phys. Rev. B, 45, 12156, 10.1103/PhysRevB.45.12156 · doi:10.1103/physrevb.45.12156
- 1988, Phys. Rev. B, 37, 2759, 10.1103/PhysRevB.37.2759 · doi:10.1103/physrevb.37.2759
- 1970, Anal. Chem., 42, 679, 10.1021/ac60288a022 · DOI · Paper page
- 1947, Wireless Engineer, 24, 35
- 1998, Rev. Sci. Instrum., 69, 3384, 10.1063/1.1149104 · doi:10.1063/1.1149104
- 1998, Concepts Magn. Reson., 10, 239, 10.1002/(SICI)1099-0534(1998)10:4<239::AID-CMR2>3.0.CO;2-Y · DOI
- 1998, Concepts Magn. Reson., 10, 133, 10.1002/(SICI)1099-0534(1998)10:3<133::AID-CMR1>3.0.CO;2-Y · DOI
Cited by
Gor’kov, P. L., Chekmenev, E. Y., Li, C., Cotten, M., Buffy, J. J., Traaseth, N. J., Veglia, G., & Brey, W. W. (2007) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.11.008 · Cited by 213
Metadata
- Authors
- Martin, R. W., Paulson, E. K., & Zilm, K. W.
- Affiliations
- Department of Chemistry, Yale University, P.O. Box 208107, New Haven, Connecticut 06520-8107
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2003-06-01
- Volume
- 74
- Issue
- 6
- Pages
- 3045-3061
- ISSN
- 0034-6748
- 1089-7623
- Cited by
- 79
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.