CoChat

Continuous wave cavity ring-down spectroscopy applied to in situ detection of dinitrogen pentoxide (N2O5)

Simpson, William R. · 2003 · Review of Scientific Instruments
Cited by 74

The DOI matches its Crossref record.

Abstract

We describe an instrument using cavity ring-down spectroscopy (CRDS), an ultrasensitive detection method, to detect NO3 and N2O5 (via thermal dissociation to NO3 at 80 °C). We use continuous-wave (cw) cavity ring-down spectroscopy, allowing a highly reliable diode laser to act as the light source. This instrument uses all solid-state laser and optical components, and it is compact, portable, and power efficient. Advantages and disadvantages of cw CRDS compared to pulsed CRDS are discussed. Inlet losses and possible interferences were extensively investigated. We show field observations of N2O5 mixing ratios in ambient air. Dinitrogen pentoxide was measured because low ambient temperatures shift the equilibrium between NO3, NO2, and N2O5 strongly towards N2O5. Therefore, only N2O5 is assumed to be present in significant quantities in Fairbanks, AK, during winter. From these data, we identify times where the N2O5 mixing ratio must be zero (due to the absence of ozone indicating presence of NO) and use these time periods to measure the system’s operational detection limit. The 2σ detection limit for N2O5 is 2.4 parts per trillion by volume (pptv) in a 25 s average. Prediction of the N2O5 detection limit from estimates of ring-down signal noise indicates a detection limit of 1.6 pptv, in the same averaging period. The observed detection limit is about 50% larger than the predicted detection limit, indicating that other noise sources affect the true detection limit. A similar instrument using pulsed CRDS was described in the last year, and we compare our instrument to this instrument for detection of N2O5.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.1578705

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 74

Metadata

Authors
Simpson, W. R.
Venue
Review of Scientific Instruments
Published
2003-07-01
Volume
74
Issue
7
Pages
3442-3452
ISSN
  • 0034-6748 (ISSN-L)
  • 1089-7623
OpenAlex
W2009165190
Cited by
74
References
0
FWCI
3.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Continuous wave cavity ring-down spectroscopy applied to in situ detection of dinitrogen pentoxide (N2O5). https://app.cochat.ai/papers/10.1063/1.1578705
The paper
Simpson, W. R. (2003). Continuous wave cavity ring-down spectroscopy applied to in situ detection of dinitrogen pentoxide (N2O5). Review of Scientific Instruments. https://doi.org/10.1063/1.1578705

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.