The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Fluorescence intensity ratio technique for optical fiber point temperature sensing
Abstract
The fluorescence intensity ratio technique for optical fiber-based point temperature sensing is reviewed, including the materials suitable for this technique. The temperature dependence of the fluorescence intensity ratio has been studied using thermally coupled energy levels in seven different rare earth ions doped into a variety of glasses and crystals. Sensor prototypes developed using Pr3+:ZBLANP, Nd3+-doped silica fiber and Yb3+-doped silica fiber as the sensing material have been used to measure temperatures covering the range of approximately −50 to 600 °C with a resolution of the order of 1 °C.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Svelto, O. (2010) · Springer eBooks · doi:10.1007/978-1-4419-1302-9 · Cited by 1,978
Rare-Earth-Doped Fiber Lasers and Amplifiers
Digonnet, M. J. F. (2026) · CRC Press eBooks · doi:10.1201/9781003528371 · Cited by 815
Optical Fiber Sensor Technology
(1998) · Springer eBooks · doi:10.1007/978-1-4615-5787-6 · Cited by 315
Cited by
Temperature Sensing Using Fluorescent Nanothermometers
Vetrone, F., Naccache, R., Zamarrón, A., Juarranz de la Fuente, A., Sanz-Rodríguez, F., Martinez Maestro, L., Martín Rodriguez, E., Jaque, D., García Solé, J., & Capobianco, J. A. (2010) · ACS Nano · doi:10.1021/nn100244a · Cited by 1,505
Upconverting Nanoparticles for Nanoscale Thermometry
Fischer, L. H., Harms, G. S., & Wolfbeis, O. S. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201006835 · Cited by 645
Lanthanides in Luminescent Thermometry
Brites, C. D. S., Millán, A., & Carlos, L. D. (2016) · Handbook on the Physics and Chemistry of Rare Earths · doi:10.1016/bs.hpcre.2016.03.005 · Cited by 536
Spotlight on Luminescence Thermometry: Basics, Challenges, and Cutting‐Edge Applications
Brites, C. D. S., Marin, R., Suta, M., Carneiro Neto, A. N., Ximendes, E., Jaque, D., & Carlos, L. D. (2023) · Advanced Materials · doi:10.1002/adma.202302749 · Cited by 464
Dong, N.-N., Pedroni, M., Piccinelli, F., Conti, G., Sbarbati, A., Ramírez-Hernández, J. E., Maestro, L. M., Iglesias-de la Cruz, M. C., Sanz-Rodriguez, F., Juarranz, A., et al. (2011) · ACS Nano · doi:10.1021/nn202490m · Cited by 427
Metadata
- Authors
- Wade, S. A., Collins, S. F., & Baxter, G. W.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 2003-10-15
- Volume
- 94
- Issue
- 8
- Pages
- 4743-4756
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2166518245
- Cited by
- 1,307
- References
- 3
- FWCI
- 7.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescence intensity ratio technique for optical fiber point temperature sensing. https://app.cochat.ai/papers/10.1063/1.1606526
- The paper
- Wade, S. A., Collins, S. F., & Baxter, G. W. (2003). Fluorescence intensity ratio technique for optical fiber point temperature sensing. Journal of Applied Physics. https://doi.org/10.1063/1.1606526
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.