CoChat

High-repetition-rate optical pulse generator using a Fabry-Perot electro-optic modulator

Kobayashi, T., Sueta, T., Cho, Y., Matsuo, Y. · 1972 · Applied Physics Letters
Cited by 140

The DOI matches its Crossref record.

Abstract

A high-repetition-rate optical pulse generator which employs a Fabry-Perot electro-optic modulator as the output coupler of a laser resonator was constructed. Using this generator with a He–Ne 6328-Å laser tube, 21-psec optical pulses at a repetition rate of 2.7 × 109 pps were experimentally obtained with an average power level of 0.5 mW. In addition, it is demonstrated that the width of the pulses obtained from this generator can be narrowed without regard to the gain-linewidth limitation. This kind of pulse generator may be particularly useful for obtaining short optical pulses from low-gain gas lasers, and it is possible to obtain 1010-pps picosecond pulses from a He–Ne 6328-Å laser.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.1654403

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 140

Metadata

Authors
Kobayashi, T., Sueta, T., Cho, Y., & Matsuo, Y.
Venue
Applied Physics Letters
Published
1972-10-15
Volume
21
Issue
8
Pages
341-343
ISSN
  • 0003-6951 (ISSN-L)
  • 1077-3118
OpenAlex
W2073606318
Cited by
140
References
0
FWCI
3.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-repetition-rate optical pulse generator using a Fabry-Perot electro-optic modulator. https://app.cochat.ai/papers/10.1063/1.1654403
The paper
Kobayashi, T., Sueta, T., Cho, Y., & Matsuo, Y. (1972). High-repetition-rate optical pulse generator using a Fabry-Perot electro-optic modulator. Applied Physics Letters. https://doi.org/10.1063/1.1654403

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.