CoChat

Microwave Surface Resistance of Superconducting Niobium

Turneaure, J. P., Weissman, Ira · 1968 · Journal of Applied Physics
Cited by 171

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

The unloaded Q's of pure Nb cavities in the TE011 mode at 11.2 GHz and in the TM010 mode at 8.4 GHz were measured between 1.2° and 4.2°K to determine whether the residual surface losses in Nb could be made sufficiently low to make it a useful material for practical microwave devices. Three forms of reactor grade Nb were evaluated: recrystallized fully wrought, arc melted, and electron-beam melted. Each of these materials was subjected to additional metallurgical processing including high-temperature vacuum firing and polishing to determine their effects on surface losses. In the TE011 mode, a residual Q of 3.8×1010 was achieved. Also in the TE011 mode, the unloaded Q was observed to be essentially a constant up to the ac critical magnetic field Hcae, where it abruptly decreased by a factor of 100 or more. An Hcae as large as 436 Oe was observed for unstrained Nb. In the TM010 mode, which has electric fields terminating on the surface of the Nb, a residual Q of 2×109 was achieved, the limitation on the maximum field level in the cavity was Hcae, and no power loss associated with electric-field emission was observed up to an electric field of 2.1×105 V/cm, which was the maximum field level obtained in the cavity. The Mattis and Bardeen theoretical expression for the superconducting surface resistance fits the data very well, and the value of the energy gap 2Δ(0) obtained from the fitting procedure is (3.72±0.01) kBTc, which agrees with values of 2Δ(0) obtained by other methods. The surface resistance data are not inconsistent with a double energy-gap model, which has been used to explain specific heat data; however, it was not possible using the data to distinguish between a double energy-gap model and a single energy-gap model with a residual surface resistance. It would be expected that Hcae would be about Hc1 where magnetic flux starts penetrating a type-II superconductor; however, the largest measured Hcae (436 Oe) was in fact about Hc1/4.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.1656986

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Turneaure, J. P., & Weissman, I.
Venue
Journal of Applied Physics
Published
1968-08-01
Volume
39
Issue
9
Pages
4417-4427
ISSN
  • 0021-8979 (ISSN-L)
  • 1089-7550
OpenAlex
W2019377473
Cited by
171
References
6
FWCI
44.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.