The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Free-volume model for ionic conductivity in polymers
Abstract
Electrical conduction in polymers under a relatively low applied electric field is considered to be ionic and is affected strongly by the structural factors of the polymers. The following equation for the electrical conductivity σ was derived in which free volume Vf, jump energy Ej, and ionic dissociation energy W were taken into consideration: σ=σ0exp{− [γ Vi*/Vf+(Ej+W/2ε)(kT)−1]}, where σo is a constant, γ the numerical factor to correct the overlap of free volume, Vi* the critical volume required for transport of an ion, ε the dielectric constant, k Boltzmann's constant, and T the absolute temperature. This equation describes well the conduction phenomena in polymethylmethacrylate, polystyrene, and an unsaturated polyester. Relationships between electrical conduction and free volume are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Viscoelastic Properties of Polymers
Ferry, J. D., & Myers, H. S. (1961) · Journal of The Electrochemical Society · doi:10.1149/1.2428174 · Cited by 13,487
Williams, M. L., Landel, R. F., & Ferry, J. D. (1955) · Journal of the American Chemical Society · doi:10.1021/ja01619a008 · Cited by 8,083
Molecular Transport in Liquids and Glasses
Cohen, M. H., & Turnbull, D. (1959) · The Journal of Chemical Physics · doi:10.1063/1.1730566 · Cited by 3,959
Properties and Structure of Polymers
Tobolsky, A. V., & Callinan, T. D. (1960) · Journal of The Electrochemical Society · doi:10.1149/1.2427514 · Cited by 1,012
The Relation of Transition Temperatures to Chemical Structure in High Polymers
Boyer, R. F. (1963) · Rubber Chemistry and Technology · doi:10.5254/1.3539649 · Cited by 723
Saito, S., Sasabe, H., Nakajima, T., & Yada, K. (1968) · Journal of Polymer Science Part A-2 Polymer Physics · doi:10.1002/pol.1968.160060708 · Cited by 138
Semiconductivity of organic substances. Part 7.—The polyamides
Eley, D. D., & Spivey, D. I. (1961) · Transactions of the Faraday Society · doi:10.1039/tf9615702280 · Cited by 85
Cited by
Electrolytes in Dye-Sensitized Solar Cells
Wu, J., Lan, Z., Lin, J., Huang, M., Huang, Y., Fan, L., & Luo, G. (2015) · Chemical Reviews · doi:10.1021/cr400675m · Cited by 977
Polymer solid electrolytes - an overview
Armand, M. (1983) · Solid State Ionics · doi:10.1016/0167-2738(83)90083-8 · Cited by 871
Novel Ferroelectric Polymers for High Energy Density and Low Loss Dielectrics
Zhu, L., & Wang, Q. (2012) · Macromolecules · doi:10.1021/ma2024057 · Cited by 683
The history of polymer electrolytes
ARMAND, M. (1994) · Solid State Ionics · doi:10.1016/0167-2738(94)90419-7 · Cited by 576
Electrical Conduction and Carrier Traps in Polymeric Materials
Ieda, M. (1984) · IEEE Transactions on Electrical Insulation · doi:10.1109/tei.1984.298741 · Cited by 312
Metadata
- Authors
- Miyamoto, T., & Shibayama, K.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 1973-12-01
- Volume
- 44
- Issue
- 12
- Pages
- 5372-5376
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2026398600
- Cited by
- 399
- References
- 7
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.