The DOI matches its Crossref record.
Four-Electrode Null Techniques for Impedance Measurement with High Resolution
Abstract
At low frequencies, the normally difficult measurement of the dielectric properties of conducting materials is severely compromised by electrode polarization. This problem at the electrode-sample interface arises from the modulation of the normal dc boundary potential by the passage of alternating current. A solution, permitting a conductance resolution of 1:105 for frequencies between 10 cps and 1 kc, is to use a second noncurrent-carrying pair of electrodes to measure the voltage across the sample and to employ a null technique for obtaining the required precision. Several four-electrode null techniques are proposed, each having certain relative merits. In all cases the resolution in capacitance is shown to be governed by a combination of the resolution in conductance, the sample properties, and the frequency of the measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
What we can do and what we cannot do with fMRI
Logothetis, N. K. (2008) · Nature · doi:10.1038/nature06976 · Cited by 3,612
Harris, C. M., Todd, R. W., Bungard, S. J., Lovitt, R. W., Morris, J. G., & Kell, D. B. (1987) · Enzyme and Microbial Technology · doi:10.1016/0141-0229(87)90075-5 · Cited by 268
Catching That Playful Beat: Social Anxiety and Synchronous Group Functioning
Gordon, I., Gilboa-Schechtman, E., Gilboa, A., Cohen, S., & Kivity, Y. (2023) · Journal of Nonverbal Behavior · doi:10.1007/s10919-023-00436-7 · Cited by 7
Metadata
- Authors
- Schwan, H. P., & Ferris, C. D.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1968-04-01
- Volume
- 39
- Issue
- 4
- Pages
- 481-485
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2076752862
- Cited by
- 193
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Four-Electrode Null Techniques for Impedance Measurement with High Resolution. https://app.cochat.ai/papers/10.1063/1.1683413
- The paper
- Schwan, H. P., & Ferris, C. D. (1968). Four-Electrode Null Techniques for Impedance Measurement with High Resolution. Review of Scientific Instruments. https://doi.org/10.1063/1.1683413
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.