The DOI matches its Crossref record; 0 of the 2 references it cites were found in a registry or an index.
Thermal Anchoring of Wires in Cryogenic Apparatus
Abstract
Thermal anchoring of wires to heat sinks in cryogenic equipment is discussed. An analysis is presented to relate the length of tempered wire required and measurable parameters of the system. The solution of the problem is included along with tabular values for typical situations.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Untitled work
(n.d.)
UnresolvedUntitled work
(n.d.)
Unresolved
Cited by
Sorted by citations
A review of cryogenic thermometry and common temperature sensors
Yeager, C. J., & Courts, S. S. (2001) · IEEE Sensors Journal · doi:10.1109/7361.983476 · Cited by 89
Critical current measurements: A compendium of experimental results
Goodrich, L. F., & Fickett, F. R. (1982) · Cryogenics · doi:10.1016/0011-2275(82)90120-5 · Cited by 79
Cryogenic thermometry: a review of recent progress
Rubin, L. G. (1970) · Cryogenics · doi:10.1016/s0011-2275(70)80004-2 · Cited by 72
A low-temperature ultrahigh vacuum scanning force microscope with a split-coil magnet
Liebmann, M., Schwarz, A., Langkat, S. M., et al. (2002) · Review of Scientific Instruments · doi:10.1063/1.1502446 · Cited by 49
Cryogenic thermometry: a review of recent progress, II
Rubin, L. G., Brandt, B. L., & Sample, H. H. (1982) · Cryogenics · doi:10.1016/0011-2275(82)90045-5 · Cited by 35
Meckler, S., Gyamfi, M., Pietzsch, O., et al. (2009) · Review of Scientific Instruments · doi:10.1063/1.3086428 · Cited by 28
Hust, J. G., Powell, R. L., & Weitzel, D. H. (1970) · Journal of Research of the National Bureau of Standards Section A Physics and Chemistry · doi:10.6028/jres.074a.056 · Cited by 28
“The length calculation has been performed (with a safety factor of about 5) as described by Hust [6] to assure a temperature difference of less than 1 mK.”
MethodSelf-citationRadebaugh, R., Frederick, N. V., & Siegwarth, J. D. (1973) · Cryogenics · doi:10.1016/0011-2275(73)90264-6 · Cited by 28
Reference tables for low-temperature thermocouples
Sparks, L. L., Powell, R. L., & Hall, W. J. (1972) · doi:10.6028/nbs.mono.124 · Cited by 15
Cryogenic Optical Lattice Clock with 1.7 × 10 − 20 Blackbody Radiation Stark Uncertainty
Hassan, Y. S., Beloy, K., Siegel, J. L., Kobayashi, T., Swiler, E., Grogan, T., Brown, R. C., Rojo, T., Bothwell, T., Hunt, B. D., et al. (2025) · Physical Review Letters · doi:10.1103/4tky-jmsm · Cited by 20
Thermal Conductivity and Thermal Diffusivity
Hust, J. G. (1983) · ASM International eBooks · doi:10.31399/asm.tb.mlt.t62860133 · Cited by 13
Self-citationContact conductance of selected metal-matrix composites
Blanchard, D. G., & Fletcher, L. S. (1995) · Journal of Thermophysics and Heat Transfer · doi:10.2514/3.679 · Cited by 11
Woven ribbon cable for cryogenic instruments
Cunningham, C. R., Hastings, P., & Strachan, J. (1995) · Cryogenics · doi:10.1016/0011-2275(95)99820-x · Cited by 10
Fickett, F. R. (1983) · ASM International eBooks · doi:10.31399/asm.tb.mlt.t62860163 · Cited by 10
Development of standards for superconductors :
Clark, A. F., Goodrich, L. F., Fickett, F. R., et al. (1982) · doi:10.6028/nbs.ir.82-1678 · Cited by 10
Axial Heat Flow Methods of Measuring Thermal Conductivity
Laubitz, M. J. (1984) · Springer eBooks · doi:10.1007/978-1-4615-6678-6_2 · Cited by 13
Relaxation calorimeter for hydrogen thermoporometry
Cleve, E. V., Worsley, M. A., & Kucheyev, S. O. (2013) · Review of Scientific Instruments · doi:10.1063/1.4803180 · Cited by 7
Jeong, S., & Kim, Y. (2009) · Cryogenics · doi:10.1016/j.cryogenics.2009.12.006 · Cited by 7
Temperature, Strain, and Magnetic Field Measurements
Sparks, L. L. (1983) · ASM International eBooks · doi:10.31399/asm.tb.mlt.t62860515 · Cited by 7
An apparatus for measurements of thermal conductivity and thermal expansion based on GM cryocooler
Liu, H., Xu, D., Xu, P., Huang, R., Xu, X., Li, L., & Gong, L. (2012) · Journal of Physics: Conference Series · doi:10.1088/1742-6596/400/5/052017 · Cited by 8
Thermal anchoring of wires in large scale superconducting coil test experiment
Patel, D., Sharma, A. N., Prasad, U., et al. (2013) · Fusion Engineering and Design · doi:10.1016/j.fusengdes.2013.03.071 · Cited by 4
The use of printed circuits in cryogenics as heat sinks for electrical temperature sensor leads
Bentley, P. D., & Wooster, W. G. (1977) · Cryogenics · doi:10.1016/0011-2275(77)90127-8 · Cited by 4
Jeong, S., & Jin, L. (2019) · Cryogenics · doi:10.1016/j.cryogenics.2019.02.010 · Cited by 3
Praktische Ausführung von Kryopumpen
Haefer, R. A. (1981) · Springer eBooks · doi:10.1007/978-3-642-49985-2_9 · Cited by 1
Beev, N., & Kiviranta, M. (2014) · Cryogenics · doi:10.1016/j.cryogenics.2014.10.001 · Cited by 1
Superconductor Measurement Techniques and Cryostat Design
Ekin, J. W. (2000) · Springer eBooks · doi:10.1007/978-94-017-0752-7_14 · Cited by 1
On the problem of thermal heat sinks in cryogenics
Velichkov, I. V. (1990) · Cryogenics · doi:10.1016/0011-2275(90)90053-f · Cited by 1
Transient Calibration of Cryogenic Thermometers
Pfotenhauer, J. M., & Cole, W. P. (2000) · Springer eBooks · doi:10.1007/978-1-4615-4215-5_112
Eder, F. X. (1981) · Springer eBooks · doi:10.1007/978-3-642-48046-1_3
Foil strip type heat sinks for low temperature use
Walstrom, P. L. (1983) · Cryogenics · doi:10.1016/0011-2275(83)90189-3
A sliding thermal tie down suitable for cryogenic temperatures in vacuum
Pavese, F. (1975) · Journal of Physics E Scientific Instruments · doi:10.1088/0022-3735/8/6/023
Kalyujnyi, M. (2012) · Science and Education of the Bauman MSTU · doi:10.7463/1212.0486450
Standard Reference Materials :
Hust, J. G., & Sparks, L. (1972) · doi:10.6028/nbs.sp.260-34
Self-citationQuinn, T. J. (1990) · Temperature · doi:10.1016/b978-0-12-569681-4.50012-9
Standards, N. B. O. (1971) · doi:10.6028/nbs.sp.340
Metadata
- Authors
- Hust, J. G.
- Affiliations
- National Institute of Standards and Technology (US)
- Corresponding author
- Hust, J. G.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1970-05-01
- Volume
- 41
- Issue
- 5
- Pages
- 622-624
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2010759563
- Semantic Scholar
- 99db0c3e568c49f2efe0ab2a068fdceb303cba6b
- Cited by
- 35
- References
- 2
- Citations by year
- 2025: 1 · 2019: 1 · 2014: 1 · 2013: 2 · 2012: 2
- FWCI
- 12.63
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Review of Scientific Instruments (publishedVersion)
- Topics
- Physical Sciences › Engineering › Aerospace Engineering › Spacecraft and Cryogenic Technologies
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting and THz Device Technology
- Keywords
- wire, heat sinks, cryogenic systems, cryogenic instrumentation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review