The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Heat Capacity Measurements on Small Samples at Low Temperatures
Abstract
We describe a new calorimeter for measuring heat capacity in the range 1–35 K, using a silicon chip bolometer as sample holder, temperature sensor, and sample heater. The apparatus is capable of measuring very small samples (1–500 mg), and may be used with a number of different experimental methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The technique is an extension of the widely applied thermal-relaxation technique.”
From Dynamic technique for measurement of the thermal conductivity and the specific heat: Application to silica aerogels (1990) · cites this paper as [2]
In the citing paper
“We should point out that the wires making up the heat leak have a nonzero heat capacity. However, assuming that the wires have a enough high thermal diffusivity, the most important effect of these wires is to enhance the heat capacity of the addenda by 1/3 of the heat capacity of the wires.²”
From Dynamic technique for measurement of the thermal conductivity and the specific heat: Application to silica aerogels (1990) · cites this paper as [2]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Carslaw, H. S., & Jaeger, J. C. (1947) · International Linear Collider · Cited by 19,877
Steady-State, ac-Temperature Calorimetry
Sullivan, P. F., & Seidel, G. (1968) · Physical Review · doi:10.1103/physrev.173.679 · Cited by 750
An advanced treatise on physical chemistry
Partington, J. R. (1949) · International Linear Collider · Cited by 398
Osborne, D. W., Flotow, H. E., & Schreiner, F. (1967) · Review of Scientific Instruments · doi:10.1063/1.1771348 · Cited by 218
Ahlers, G. (1966) · Review of Scientific Instruments · doi:10.1063/1.1720219 · Cited by 83
Cited by
Vibrational thermodynamics of materials
Fultz, B. (2010) · Progress in Materials Science · doi:10.1016/j.pmatsci.2009.05.002 · Cited by 696
Low-frequency modes in vitreous silica
Buchenau, U., Prager, M., Nücker, N., Dianoux, A. J., Ahmad, N., & Phillips, W. A. (1986) · Physical Review B · doi:10.1103/physrevb.34.5665 · Cited by 564
Measurement of low-temperature specific heat
Stewart, G. R. (1983) · Review of Scientific Instruments · doi:10.1063/1.1137207 · Cited by 422
Kim, H. J., Kim, U., Kim, T. H., Kim, J., Kim, H. M., Jeon, B.-G., Lee, W.-J., Mun, H. S., Hong, K. T., Yu, J., et al. (2012) · Physical Review B · doi:10.1103/physrevb.86.165205 · Cited by 320
Magnetothermal properties of molecule-based materials
Evangelisti, M., Luis, F., de Jongh, L. J., & Affronte, M. (2006) · Journal of Materials Chemistry · doi:10.1039/b603738k · Cited by 315
Metadata
- Authors
- Bachmann, R., DiSalvo, F. J., Geballe, T. H., Greene, R. L., Howard, R. E., King, C. N., Kirsch, H. C., Lee, K. N., Schwall, R. E., Thomas, H.-U., & Zubeck, R. B.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1972-02-01
- Volume
- 43
- Issue
- 2
- Pages
- 205-214
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2140697562
- Cited by
- 556
- References
- 5
- FWCI
- 15.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.