Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 508

The DOI matches its Crossref record.

X-Ray Diffractometry of Low-Temperature Phase Transformations in Strontium Titanate

Lytle, Farrel W.·1964·Journal of Applied Physics

Abstract

The lattice parameters of single-crystal SrTiO3 were determined by x-ray diffraction as a function of temperature from 4.2° to 300°K. In addition to the normal cubic structure three significant regions were found. From 65° to 100°K a tetragonal modification exists (c/a=1.00056), from 35° to 55°K line splitting consistent with orthorhombic symmetry was observed, and at 10°K an anomalous maximum in the lattice parameter vs temperature curve was found which suggested a third structure transformation. In the tetragonal region (at 78°K) various domain configurations were photographed with a polarizing microscope.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.1702820

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 508

Metadata

Authors
Lytle, F. W.
Venue
Journal of Applied Physics
Published
1964-07-01
Volume
35
Issue
7
Pages
2212-2215
ISSN
  • 0021-8979 (ISSN-L)
  • 1089-7550
OpenAlex
W1985710990
Cited by
508
References
0
FWCI
12.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: X-Ray Diffractometry of Low-Temperature Phase Transformations in Strontium Titanate. https://app.cochat.ai/papers/10.1063/1.1702820
The paper
Lytle, F. W. (1964). X-Ray Diffractometry of Low-Temperature Phase Transformations in Strontium Titanate. Journal of Applied Physics. https://doi.org/10.1063/1.1702820

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.