The DOI matches its Crossref record.
An X-Ray Method of Determining Rates of Diffusion in the Solid State
Open accessAbstract
Gold and copper were simultaneously deposited in vacuum by vaporization on a plate of glass, the copper being deposited at a uniform rate while the gold was deposited in one hundred stratified layers in the copper by alternately raising and lowering the temperature of the molybdenum vaporizing trough containing the boiling gold. The translucent deposit so formed had a total thickness of about 10,000A and hence an average interplanar distance of 100A. In an especially constructed constructed x-ray spectrograph selective diffraction of Mo K radiation from these stratified films was observed corresponding to the artificially imposed periodicity of the stratification and the intensity of this diffracted image relative to the direct beam was found to fall off with time so as to indicate a "half-life" for the stratified structure of about two days. This suggests a general method for the study of average rates of diffusion and the determination of diffusion coefficients of solids in solids by utilizing the decay of such stratified films. Simple theoretical considerations should, through the action of diffusion alone, rapidly and automatically lose the higher Fourier harmonics of its periodic density distribution function and retain the fundamental in such a way as to render the determination of the diffusion coefficient quite accurate. The observed behavior of the diffracted maxima seem to support these expectations as does also the absence of any intensity in higher orders than the first. This purification by diffusion probably takes place principally during the depositing process itself while the temperatures are still quite high. Formulae are derived relating the observed rate of decay of the diffracted intensity, the artificial "grating coefficient" of the strata, and the diffusion coefficient. The method seems especially promising for substances and temperatures where diffusion is so slow as to be otherwise quite unobservable because the diffusion time varies as the square of the distance over which atoms must migrate and in this method these distances are so many orders of magnitude smaller than in any other.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Underwood, J. H., & Barbee, T. W. (1981) · Applied Optics · doi:10.1364/ao.20.003027 · Cited by 372
Molybdenum-silicon multilayer mirrors for the extreme ultraviolet
Barbee, T. W., Mrowka, S., & Hettrick, M. C. (1985) · Applied Optics · doi:10.1364/ao.24.000883 · Cited by 220
Metadata
- Authors
- DuMond, J., & Youtz, J. P.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 1940-05-01
- Volume
- 11
- Issue
- 5
- Pages
- 357-365
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2155966253
- Cited by
- 199
- References
- 0
- FWCI
- 1.07
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An X-Ray Method of Determining Rates of Diffusion in the Solid State. https://app.cochat.ai/papers/10.1063/1.1712784
- The paper
- DuMond, J., & Youtz, J. P. (1940). An X-Ray Method of Determining Rates of Diffusion in the Solid State. Journal of Applied Physics. https://doi.org/10.1063/1.1712784
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.