Modified Spin-Echo Method for Measuring Nuclear Relaxation Times
Abstract
A spin echo method adapted to the measurement of long nuclear relaxation times (T2) in liquids is described. The pulse sequence is identical to the one proposed by Carr and Purcell, but the rf of the successive pulses is coherent, and a phase shift of 90° is introduced in the first pulse. Very long T2 values can be measured without appreciable effect of diffusion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These structural fluctuations can be detected using Carr-Purcell-Meiboom-Gill (CPMG) relaxation dispersion experiments, [20, 21] which provide residue-specific relaxation dispersion curves that are used to quantify kinetics (exchange constant, kex) and thermodynamic (populations, pA and pA’) parameters for exchange processes occurring on the μs-ms timescale.[3]”
From Unbiased Clustering of Residues Undergoing Synchronous Motions in Proteins Using Nmr Spin Relaxation Data (2025) · cites this paper as [21]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Hahn, E. L. (1950) · Physical Review · doi:10.1103/physrev.80.580 · Cited by 5,085
Bloch, F. (1946) · Physical Review · doi:10.1103/physrev.70.460 · Cited by 3,676
Use of Rotating Coordinates in Magnetic Resonance Problems
Rabi, I. I., Ramsey, N. F., & Schwinger, J. (1954) · Reviews of Modern Physics · doi:10.1103/revmodphys.26.167 · Cited by 439
Cited by
From Microporous to Mesoporous Molecular Sieve Materials and Their Use in Catalysis
Corma, A. (1997) · Chemical Reviews · doi:10.1021/cr960406n · Cited by 5,791
Ladd, T. D., Jelezko, F., Laflamme, R., Nakamura, Y., Monroe, C., & O’Brien, J. L. (2010) · Nature · doi:10.1038/nature08812 · Cited by 3,592
Beckonert, O., Keun, H. C., Ebbels, T. M. D., Bundy, J., Holmes, E., Lindon, J. C., & Nicholson, J. K. (2007) · Nature Protocols · doi:10.1038/nprot.2007.376 · Cited by 2,109
Farrow, N. A., Muhandiram, R., Singer, A. U., Pascal, S. M., Kay, C. M., Gish, G., Shoelson, S. E., Pawson, T., Forman-Kay, J. D., & Kay, L. E. (1994) · Biochemistry · doi:10.1021/bi00185a040 · Cited by 2,091
RARE imaging: A fast imaging method for clinical MR
Hennig, J., Nauerth, A., & Friedburg, H. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030602 · Cited by 2,081
Metadata
- Authors
- Meiboom, S., & Gill, D.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1958-08-01
- Volume
- 29
- Issue
- 8
- Pages
- 688-691
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2076283593
- Cited by
- 6,022
- References
- 4
- FWCI
- 4.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.