Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 562

The DOI matches its Crossref record.

A Mass Spectrometer for Isotope and Gas Analysis

Nier, Alfred O.·1947·Review of Scientific Instruments

Abstract

A mass spectrometer suitable for routine isotope analyses of the lighter elements is described. Complete electronic circuits are given. An all metal mass spectrometer tube is employed. A null method of determining relative abundances of the elements carbon, nitrogen, and oxygen is used. Although designed primarily for analyzing elements for which separated isotopes are available as tracers, the instrument may be modified for use over the entire atomic table or for making gas analyses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.1740961

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Metadata

Authors
Nier, A. O.
Venue
Review of Scientific Instruments
Published
1947-06-01
Volume
18
Issue
6
Pages
398-411
ISSN
  • 0034-6748 (ISSN-L)
  • 1089-7623
OpenAlex
W2171826134
Cited by
562
References
0
FWCI
14.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Mass Spectrometer for Isotope and Gas Analysis. https://app.cochat.ai/papers/10.1063/1.1740961
The paper
Nier, A. O. (1947). A Mass Spectrometer for Isotope and Gas Analysis. Review of Scientific Instruments. https://doi.org/10.1063/1.1740961

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.