Use of the Piezoelectric Gauge for Internal Friction Measurements
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The addition of an auxiliary quartz crystal to the usual composite piezoelectric resonator provides a convenient strain gauge, which simplifies the measurement procedure and permits the evaluation of amplitude dependent decrements over a wide range of strain amplitudes. A unique feature of the new procedure is that virtually instantaneous values of the decrement are obtained, thus bringing transient internal friction phenomena under observation. Mechanical resonance frequencies may be precisely determined for high as well as low decrement specimens. The numerical evaluation of terms is carried out for a recommended driver-gauge construction of 18.5° X-cut quartz bars.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Voigt, W. (1966) · Vieweg+Teubner eBooks · doi:10.1007/978-3-663-15884-4 · Cited by 3,723
The Piezo-Electric Resonator and Its Equivalent Network
Van Dyke, K. S. (1928) · Proceedings of the IRE · doi:10.1109/jrproc.1928.221466 · Cited by 292
On Electrically-maintained Vibrations
Butterworth, S. (1914) · Proceedings of the Physical Society of London · doi:10.1088/1478-7814/27/1/330 · Cited by 121
The Variation with Temperature of the Principal Elastic Moduli of NaCl near the Melting Point
Hunter, L. P. (1942) · Physical Review · doi:10.1103/physrev.61.84 · Cited by 110
Cited by
The ultrasonic modulation technique of determining strain effects in ESR
Robinson, W. H., Collins, M. A., & Devine, S. D. (1975) · Journal of Physics E: Scientific Instruments · doi:10.1088/0022-3735/8/2/022 · Cited by 13
Metadata
- Authors
- Marx, J.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1951-07-01
- Volume
- 22
- Issue
- 7
- Pages
- 503-509
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2073173437
- Cited by
- 285
- References
- 4
- FWCI
- 5.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.