The DOI matches its Crossref record.
Rapid and Sensitive Spectrophotometry. III. A Double Beam Apparatus
Abstract
An apparatus for accurately timing the sequence of spectroscopic events in turbid suspensions of the cytochrome oxidase system has been developed. This apparatus measures simultaneously small optical density changes occurring at two wavelengths in the visible region with a small spectral interval in spite of the large scattering of light by the heart muscle suspensions. The cross talk between the two channels corresponds to an optical density change of less than 5×10−4. Transients arising from the modulation and demodulation processes cause no difficulty. The error of optical measurements caused by the noise level in the photocurrent is 2×10−4 for a rise time (10–90 percent) of 1 sec. Some typical experimental results are included.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
The Assay of Catalases and Peroxidases
Maehly, A. C. (1954) · Methods of Biochemical Analysis · doi:10.1002/9780470110171.ch14 · Cited by 3,303
Pigments of rat liver microsomes
Klingenberg, M. (1958) · Archives of Biochemistry and Biophysics · doi:10.1016/0003-9861(58)90436-3 · Cited by 664
[2] Citrate synthase from rat liver
Shepherd, D., & Garland, P. B. (1969) · Methods in Enzymology · doi:10.1016/0076-6879(69)13006-2 · Cited by 434
Pigments of rat liver microsomes
Klingenberg, M. (2003) · Archives of Biochemistry and Biophysics · doi:10.1016/s0003-9861(02)00621-5 · Cited by 411
The Interaction of Energy and Electron Transfer Reactions in Mitochondria
Chance, B., & Hollunger, G. (1961) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)64210-3 · Cited by 363
Self-citationNon-invasive NIR spectroscopy of human brain function during exercise
Perrey, S. (2008) · Methods · doi:10.1016/j.ymeth.2008.04.005 · Cited by 346
Time-resolved spectroscopy of hemoglobin and myoglobin in resting and ischemic muscle
Chance, B., Nioka, S., Kent, J., McCully, K., Fountain, M., Greenfeld, R., & Holtom, G. (1988) · Analytical Biochemistry · doi:10.1016/0003-2697(88)90076-0 · Cited by 329
Self-citationOxygen in mammalian tissue: methods of measurement and affinities of various reactions
Vanderkooi, J. M., Erecinska, M., & Silver, I. A. (1991) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1991.260.6.c1131 · Cited by 277
In Vivo Near-Infrared Spectroscopy
Rolfe, P. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.715 · Cited by 273
Metadata
- Authors
- Chance, B.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1951-08-01
- Volume
- 22
- Issue
- 8
- Pages
- 634-638
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2014758513
- Cited by
- 296
- References
- 0
- FWCI
- 6.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.