The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Fast microtomography using high energy synchrotron radiation
Abstract
At the High Energy Beamline ID15A at the European Synchrotron Radiation Facility we have developed a fast three-dimensional x-ray microtomography system, which acquires a complete dataset in typically less than 10s. This unprecedented speed is achieved by combining a high efficiency phosphor screen, a reflecting microscope objective and a fast charge coupled device detector with the very intense high-energy white beam radiation provided by a wiggler source. The achieved spatial resolution is 2μm. The available x-ray energy spectrum spans from 20to250keV and can therefore be used for low and high Z materials. The spectrum can be modified by inserting different filters into the x-ray beam in order to optimize the signal-to-noise ratio and to avoid beam-hardening artifacts. Different phosphors with different energy sensitivity can be used. The very high speed allows in situ studies of systems evolving on the time scale of a few seconds or minutes. Three examples are given on sintering of metallic powders, solidification of binary alloys and liquid front propagation in granular materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Cited by
Maire, E., & Withers, P. J. (2014) · International Materials Reviews · doi:10.1179/1743280413y.0000000023 · Cited by 1,374
Wildenschild, D., & Sheppard, A. P. (2013) · Advances in Water Resources · doi:10.1016/j.advwatres.2012.07.018 · Cited by 1,239
In-operando high-speed tomography of lithium-ion batteries during thermal runaway
Finegan, D. P., Scheel, M., Robinson, J. B., Tjaden, B., Hunt, I., Mason, T. J., Millichamp, J., Di Michiel, M., Offer, G. J., Hinds, G., et al. (2015) · Nature Communications · doi:10.1038/ncomms7924 · Cited by 844
Recent advances in X-ray microtomography applied to materials
Stock, S. R. (2008) · International Materials Reviews · doi:10.1179/174328008x277803 · Cited by 517
Regridding reconstruction algorithm for real-time tomographic imaging
Marone, F., & Stampanoni, M. (2012) · Journal of Synchrotron Radiation · doi:10.1107/s0909049512032864 · Cited by 441
Metadata
- Authors
- Di Michiel, M., Merino, J. M., Fernandez-Carreiras, D., Buslaps, T., Honkimäki, V., Falus, P., Martins, T., & Svensson, O.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2005-03-18
- Volume
- 76
- Issue
- 4
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2022027522
- Cited by
- 169
- References
- 1
- FWCI
- 12.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fast microtomography using high energy synchrotron radiation. https://app.cochat.ai/papers/10.1063/1.1884194
- The paper
- Di Michiel, M., Merino, J. M., Fernandez-Carreiras, D., Buslaps, T., Honkimäki, V., Falus, P., Martins, T., & Svensson, O. (2005). Fast microtomography using high energy synchrotron radiation. Review of Scientific Instruments. https://doi.org/10.1063/1.1884194
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.