Abstract

The real and imaginary parts of the refractive index, n(ω) and k(ω), of silicon were measured as a function of photon frequency ω using Fourier transform infrared (FTIR) transmission spectral data. An accurate mechanical measurement of the wafer’s thickness, t, was required, and two FTIR spectra were used: one of high resolution (Δω=0.1to0.5cm−1) yielding a typical channel spectrum (Fabry–Perot fringes) dependent mainly on t and n(ω), and one of low resolution (Δω=4.0cm−1) yielding an absorption spectrum dependent mainly on t and k(ω). A procedure was developed to first get initial estimates for n(ω) for the high-resolution spectrum and then calculate k(ω) from the faster low-resolution spectrum with minimal measurement drift. Then both initial n and final k values were used together as starting point data for a fit to the high-resolution spectrum. A previously derived transmission formula for a convergent incident beam was used for the fit. The accuracy of n(ω) determined using this procedure is mostly dependent upon the measurement error in the sample thickness t and k(ω) is dominated by the accuracy of the absolute transmission values obtained from a sample-in and sample-out methods. Our results are compared with previously published values for n(ω) and k(ω) in the 450–4000-cm−1 spectral region. The reported uncertainty in n(ω) is ±10−4 absolute, a factor of 10 better than published values. The values of n(ω) range from 3.4400 at 4000cm−1 (λ=2.5μm) to 3.4169 at 450cm−1 (λ=22.222μm). The k(ω) values had a standard deviation of ⩽±3% and are in good agreement with previous measurements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.1923612

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 202

Metadata

Authors
Chandler-Horowitz, D., & Amirtharaj, P. M.
Venue
Journal of Applied Physics
Published
2005-06-15
Volume
97
Issue
12
ISSN
  • 0021-8979 (ISSN-L)
  • 1089-7550
OpenAlex
W2038087133
Cited by
202
References
0
FWCI
0.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-accuracy, midinfrared (450cm−1⩽ω⩽4000cm−1) refractive index values of silicon. https://app.cochat.ai/papers/10.1063/1.1923612
The paper
Chandler-Horowitz, D., & Amirtharaj, P. M. (2005). High-accuracy, midinfrared (450cm−1⩽ω⩽4000cm−1) refractive index values of silicon. Journal of Applied Physics. https://doi.org/10.1063/1.1923612

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.