The DOI matches its Crossref record.
A quasioptical transient electron spin resonance spectrometer operating at 120 and 240 GHz
Abstract
A new multifrequency quasioptical electron paramagnetic resonance (EPR) spectrometer is described. The superheterodyne design with Schottky diode mixer/detectors enables fast detection with subnanosecond time resolution. Optical access makes it suitable for transient EPR (TR-EPR) at 120 and 240 GHz. These high frequencies allow for an accurate determination of small g-tensor anisotropies as are encountered in excited triplet states of organic molecules like porphyrins and fullerenes. The measured concentration sensitivity for continuous-wave (cw) EPR at 240 GHz and at room temperature without cavity is 1013spins∕cm3 (15 nM) for a 1 mT linewidth and a 1 Hz bandwidth. With a Fabry-Perot cavity and a sample volume of 30 nl, the sensitivity at 240 GHz corresponds to ≈3×109 spins for a 1 mT linewidth. The spectrometer’s performance is illustrated with applications of transient EPR of excited triplet states of organic molecules, as well as cw EPR of nitroxide reference systems and a thin film of a colossal magnetoresistance material.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Subterahertz spin pumping from an insulating antiferromagnet
Vaidya, P., Morley, S. A., van Tol, J., Liu, Y., Cheng, R., Brataas, A., Lederman, D., & del Barco, E. (2020) · Science · doi:10.1126/science.aaz4247 · Cited by 318
Self-citationQuenching Spin Decoherence in Diamond through Spin Bath Polarization
Takahashi, S., Hanson, R., van Tol, J., Sherwin, M. S., & Awschalom, D. D. (2008) · Physical Review Letters · doi:10.1103/physrevlett.101.047601 · Cited by 272
Self-citationMentink-Vigier, F., Marin-Montesinos, I., Jagtap, A. P., Halbritter, T., van Tol, J., Hediger, S., Lee, D., Sigurdsson, S. T., & De Paëpe, G. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.8b04911 · Cited by 171
Self-citation
Metadata
- Authors
- van Tol, J., Brunel, L.-C., & Wylde, R. J.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2005-06-22
- Volume
- 76
- Issue
- 7
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2087257431
- Cited by
- 168
- References
- 0
- FWCI
- 5.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A quasioptical transient electron spin resonance spectrometer operating at 120 and 240 GHz. https://app.cochat.ai/papers/10.1063/1.1942533
- The paper
- van Tol, J., Brunel, L.-C., & Wylde, R. J. (2005). A quasioptical transient electron spin resonance spectrometer operating at 120 and 240 GHz. Review of Scientific Instruments. https://doi.org/10.1063/1.1942533
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.