CoChat

Gas-phase electronic spectra of C18 and C22 rings

Boguslavskiy, A. E., Ding, H., Maier, J. P. · 2005 · The Journal of Chemical Physics
Cited by 55

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

The electronic spectra of C18 and C22 in the 15150–36900cm−1 range have been detected in the gas phase by a mass-selective resonant two-color two-photon ionization technique coupled to a laser ablation source. The spectra were assigned to several electronic systems of monocyclic cumulenic isomers with a D9h symmetry for C18 and D11h for C22, based on time-dependent-density-functional calculations and reactivity with respect to H2. The best cooling conditions were achieved with Kr as the buffer gas, and the origin of the Ã1A2″←X̃1A1′ transition of C18 at 592.89nm shows a pair of 1cm−1 broadbands spaced by 1.5cm−1. The next electronic transitions exhibited much broader, ∼30 (in the visible) to 200cm−1 (in ultraviolet range), features. The spectrum of C22 exhibits an absorption pattern similar to C18, except that the narrow features to the red are missing; the oscillator strength of the Ã←X̃ transition is predicted to be low.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.1961564

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 55

Metadata

Authors
Boguslavskiy, A. E., Ding, H., & Maier, J. P.
Venue
The Journal of Chemical Physics
Published
2005-07-15
Volume
123
Issue
3
Pages
34305-34305
ISSN
  • 0021-9606 (ISSN-L)
  • 1089-7690
OpenAlex
W1578088717
Cited by
55
References
5
FWCI
2.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Gas-phase electronic spectra of C18 and C22 rings. https://app.cochat.ai/papers/10.1063/1.1961564
The paper
Boguslavskiy, A. E., Ding, H., & Maier, J. P. (2005). Gas-phase electronic spectra of C18 and C22 rings. The Journal of Chemical Physics. https://doi.org/10.1063/1.1961564

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.