Nuclear magnetic resonance in the nanoTesla range
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
At ultralow fields of 40nTto4μT magnetic flux density, nuclear magnetic resonance spectra of a resolution well below 1Hz were obtained, which is beyond what usually is achieved in the conventional high-field regime. The spectral resolution of our setup allows for the direct observation of the natural linewidth of distilled water. For heteronuclear systems, this enables pure J-spectroscopy in the absence of a chemical shift, with a resolution that is limited only by the natural width of the resonance lines.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Also MCG and NMR signals could already be detected using the same SQUID instrumentation [46].”
From Biomagnetism using SQUIDs: status and perspectives (2006) · cites this paper as [46]
Citations
Cites
The Principles of Nuclear Magnetism
Abragam, A., & Hebel, L. C. (1961) · American Journal of Physics · doi:10.1119/1.1937646 · Cited by 15,792
Liquid-State NMR and Scalar Couplings in Microtesla Magnetic Fields
McDermott, R., Trabesinger, A. H., Mück, M., Hahn, E. L., Pines, A., & Clarke, J. (2002) · Science · doi:10.1126/science.1069280 · Cited by 300
Application of superconducting quantum interference devices to nuclear magnetic resonance
Greenberg, Y. S. (1998) · Reviews of Modern Physics · doi:10.1103/revmodphys.70.175 · Cited by 214
Simultaneous magnetoencephalography and SQUID detected nuclear MR in microtesla magnetic fields
Volegov, P., Matlachov, A. N., Espy, M. A., George, J. S., & Kraus, R. H. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20193 · Cited by 80
Proton spin T 1 relaxation dispersion in liquid H2O by slow proton-exchange
Graf, V., Noack, F., & Béné, G. J. (1980) · The Journal of Chemical Physics · doi:10.1063/1.439240 · Cited by 76
Seton, H. C., Hutchison, J. M. S., & Bussell, D. M. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/2/015 · Cited by 71
A SQUID measurement system for immunoassays
Matz, H., Drung, D., Hartwig, S., Groß, H., Kötitz, R., Müller, W., Vass, A., Weitschies, W., & Trahms, L. (1999) · Applied Superconductivity · doi:10.1016/s0964-1807(99)00014-9 · Cited by 68
Self-citationThe Berlin Magnetically Shielded Room (BMSR) Section B - Performances
Erne, S. N., Hahlbohm, H.-D., Scheer, H.-J., & Trontelj, Z. (1981) · De Gruyter eBooks · doi:10.1515/9783110863529-006 · Cited by 66
SQUID-Detected Liquid State NMR in Microtesla Fields
Trabesinger, A. H., McDermott, R., Lee, S., Mück, M., Clarke, J. L., & Pines, A. (2004) · The Journal of Physical Chemistry A · doi:10.1021/jp035181g · Cited by 63
NMR and MRI obtained with high transition temperature dc SQUIDs
de Souza, R. E., Schlenga, K., Wong-Foy, A., McDermott, R., Pines, A., & Clarke, J. L. (1999) · Journal of the Brazilian Chemical Society · doi:10.1590/s0103-50531999000400009 · Cited by 17
Research works printed but not linked: 1
- 1954, Phys. Rev., 93, 941
Cited by
SQUID-Detected Magnetic Resonance Imaging in Microtesla Fields
Clarke, J., Hatridge, M., & Mößle, M. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.152010 · Cited by 205
Biomagnetism using SQUIDs: status and perspectives
Sternickel, K., & Braginski, A. I. (2006) · Superconductor Science and Technology · doi:10.1088/0953-2048/19/3/024 · Cited by 180
Chemical analysis by ultrahigh-resolution nuclear magnetic resonance in the Earth’s magnetic field
Appelt, S., Kühn, H., Häsing, F. W., & Blümich, B. (2006) · Nature Physics · doi:10.1038/nphys211 · Cited by 160
“Heteronuclear J -coupling constants have been measured with a spectral resolution of about 1 Hz in the micro- and nanotesla regim”
MethodSQUID-based instrumentation for ultralow-field MRI
Zotev, V. S., Matlashov, A. N., Volegov, P. L., Urbaitis, A. V., Espy, M. A., & Kraus, R. H., Jr. (2007) · Superconductor Science and Technology · doi:10.1088/0953-2048/20/11/s13 · Cited by 108
Zhukov, I. V., Kiryutin, A. S., Yurkovskaya, A. V., Grishin, Y. A., Vieth, H., & Ivanov, K. L. (2018) · Physical Chemistry Chemical Physics · doi:10.1039/c7cp08529j · Cited by 100
Toward direct neural current imaging by resonant mechanisms at ultra-low field
Kraus, R. H., Volegov, P. L., Matlachov, A. N., & Espy, M. A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.07.058 · Cited by 94
“Our group (Matlachov et al., 2004) and others (McDermott et al., 2004; Burghoff et al., 2005) have experimentally demonstrated ULF-MRI, using fields 104–106 times weaker than HF-MRI.”
MethodA new cryogenic apparatus to search for the neutron electric dipole moment
Ahmed, M. W., Alarcón, R., Aleksandrova, A., Baeßler, S., Barrón-Palos, L., Bartoszek, L., howard, B. D., Behzadipour, M., Berkutov, I. B., Bessuille, J., et al. (2019) · Journal of Instrumentation · doi:10.1088/1748-0221/14/11/p11017 · Cited by 84
“Magnetic field sensitivities of ≈1 fT/ √ Hz are routinely achieved in ultra-low field nuclear magnetic resonance (NMR) experiments [66, 67].”
BackgroundParallel MRI at microtesla fields
Zotev, V. S., Volegov, P. L., Matlashov, A. N., Espy, M. A., Mosher, J. C., & Kraus, R. H. (2008) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2008.02.015 · Cited by 80
“Because of this, ultra-low fields of modest relative homogeneity are highly homogeneous on the absolute scale, and very narrow NMR lines with high SNR are achieved [16,20,26].”
BackgroundMethodInfluentialSQUID-detected ultra-low field MRI
Espy, M. A., Matlashov, A. N., & Volegov, P. L. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2013.02.009 · Cited by 67
RetractedMRI of the human brain at 130 microtesla
Inglis, B. A., Buckenmaier, K., SanGiorgio, P., Pedersen, A. F., Nichols, M. A., & Clarke, J. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1319334110 · Cited by 63
Low-cost, pseudo-Halbach dipole magnets for NMR
Tayler, M. C. D., & Sakellariou, D. (2017) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2017.03.001 · Cited by 60
“sub-ppm field uniformity, for example nuclear prepolarization of samples prior to remote detection of the signal in earth’s field[15] or ultra-low field.[16, 17, 27] In some cases the magnetic field homogeneity may be acceptable for in situ high-resolution NMR spectroscopy of small-volume samples, which are less sus-”
Yang, H.-C., Liao, S.-H., Horng, H. E., Kuo, S.-L., Chen, H.-H., & Yang, S. (2006) · Applied Physics Letters · doi:10.1063/1.2216904 · Cited by 57
J-Coupling Nuclear Magnetic Resonance Spectroscopy of Liquids in nT Fields
Bernarding, J., Buntkowsky, G., Macholl, S., Hartwig, S., Burghoff, M., & Trahms, L. (2005) · Journal of the American Chemical Society · doi:10.1021/ja055273e · Cited by 57
Self-citationMagnetic Gradiometer for the Detection of Zero- to Ultralow-Field Nuclear Magnetic Resonance
Jiang, M., Picazo‐Frutos, R., Wu, T., Blanchard, J. W., Peng, X., & Budker, D. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.11.024005 · Cited by 53
Trahms, L., & Burghoff, M. (2010) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2010.02.004 · Cited by 47
“• Multichannel recordings of the spatially distributed magnetic MR signal are interpreted by inverse reconstruction algorithms [8].”
BackgroundMethodSelf-citationQiu, L., Zhang, Y., Krause, H., Braginski, A. I., Burghoff, M., & Trahms, L. (2007) · Applied Physics Letters · doi:10.1063/1.2771060 · Cited by 46
Self-citationNMR field-cycling at ultralow magnetic fields
Kresse, B., Privalov, A. F., & Fujara, F. (2011) · Solid State Nuclear Magnetic Resonance · doi:10.1016/j.ssnmr.2011.10.002 · Cited by 45
1 H NMR at Larmor frequencies down to 3 Hz by means of Field-Cycling techniques
Kresse, B., Becher, M., Privalov, A. F., Hofmann, M., Rössler, E. A., Vogel, M., & Fujara, F. (2017) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2017.02.002 · Cited by 42
Phenomena in J -coupled nuclear magnetic resonance spectroscopy in low magnetic fields
Appelt, S., Häsing, F. W., Kühn, H., & Blümich, B. (2007) · Physical Review A · doi:10.1103/physreva.76.023420 · Cited by 42
Solving the problem of concomitant gradients in ultra-low-field MRI
Nieminen, J. O., & Ilmoniemi, R. J. (2010) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2010.09.001 · Cited by 41
“For the water, we assumed relaxation times T1 = T2 = 2 s [24].”
BackgroundNMR in the Earth’s magnetic field
Mohorič, A., & Stepišnik, J. (2008) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2008.07.002 · Cited by 41
“The first observation of homonuclear proton J-couplings in the Earth’s magnetic field, which earlier seemed to be impossible [35,36], was recently reported [37].”
BackgroundZhang, Y., Qiu, L., Krause, H., Hartwig, S., Burghoff, M., & Trahms, L. (2007) · Applied Physics Letters · doi:10.1063/1.2734896 · Cited by 41
Self-citationMultiplets at zero magnetic field: The geometry of zero-field NMR
Butler, M. C., Ledbetter, M. P., Theis, T., Blanchard, J. W., Budker, D., & Pines, A. (2013) · The Journal of Chemical Physics · doi:10.1063/1.4803144 · Cited by 42
Analysis of molecular structures by homo- and hetero-nuclear J-coupled NMR in ultra-low field
Appelt, S., Häsing, F. W., Kühn, H., Sieling, U., & Blümich, B. (2007) · Chemical Physics Letters · doi:10.1016/j.cplett.2007.03.096 · Cited by 39
Liao, S.-H., Huang, K., Yang, H.-C., Yen, C.-T., Chen, M. J., Chen, H.-H., Horng, H. E., & Yang, S. Y. (2010) · Applied Physics Letters · doi:10.1063/1.3530124 · Cited by 38
Nuclear magnetic relaxation in water revisited
Hartwig, S., Voigt, J., Scheer, H.-J., Albrecht, H.-H., Burghoff, M., & Trahms, L. (2011) · The Journal of Chemical Physics · doi:10.1063/1.3623024 · Cited by 38
Self-citationNuclear magnetic resonance at millitesla fields using a zero-field spectrometer
Tayler, M. C. D., Sjolander, T. F., Pines, A., & Budker, D. (2016) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2016.05.010 · Cited by 34
“[15, 16, 17, 18, 19] As an alternative to previous ZULF NMR measurements using superconducting quantum interference devices,[20, 21, 22, 23, 24, 25] an inexpensive optical magnetometer obviates the need for cryogenics, adding to the potential mobility of the device.”
MethodNew Zealand Developments in Earth's Field NMR
Callaghan, P. T., Coy, A., Dykstra, R., Eccles, C. D., Halse, M. E., Hunter, M. W., Mercier, O., & Robinson, J. N. (2007) · Applied Magnetic Resonance · doi:10.1007/s00723-007-0012-5 · Cited by 34
Are brain currents detectable by means of low-field NMR? A phantom study
Höfner, N., Albrecht, H.-H., Cassara, A. M., Curio, G., Hartwig, S., Haueisen, J., Hilschenz, I., Körber, R., Martens, S., Scheer, H.-J., et al. (2011) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2011.07.009 · Cited by 33
“The usage of NMR in very low magnetic fields has the additional advantage that the absolute inhomogeneity of the magnetic field of a coil scales with the field strength as well, permitting the use of simple coil designs in the low-field regime [15,16].”
BackgroundSelf-citationSQUID Systems Adapted to Record Nuclear Magnetism in Low Magnetic Fields
Burghoff, M., Hartwig, S., Kilian, W., Vorwerk, A., & Trahms, L. (2007) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2007.898203 · Cited by 33
Self-citationOn the feasibility of neurocurrent imaging by low-field nuclear magnetic resonance
Burghoff, M., Albrecht, H.-H., Hartwig, S., Hilschenz, I., Körber, R., Höfner, N., Scheer, H.-J., Voigt, J., Trahms, L., & Curio, G. (2010) · Applied Physics Letters · doi:10.1063/1.3441410 · Cited by 30
Self-citationLiao, S.-H., Yang, H.-C., Horng, H. E., Yang, S.-Y., Chen, H. H., Hwang, D. W., & Hwang, L. P. (2009) · Superconductor Science and Technology · doi:10.1088/0953-2048/22/4/045008 · Cited by 28
Low-field NMR measurement procedure when SQUID detection is used
Qiu, L., Zhang, Y., Krause, H., Braginski, A. I., & Offenhäusser, A. (2008) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2008.09.009 · Cited by 27
“(1) This requirement is easily met for a laboratory SQUID instrumentation operating in ultralow field NMR [4].”
BackgroundLiao, S.-H., Horng, H. E., Yang, H.-C., & Yang, S. (2007) · Journal of Applied Physics · doi:10.1063/1.2767193 · Cited by 26
Squid system for meg and low field magnetic resonance
Burghoff, M., Albrecht, H.-H., Hartwig, S., Hilschenz, I., Körber, R., Thömmes, T. S., Scheer, H.-J., Voigt, J., & Trahms, L. (2009) · Metrology and Measurement Systems · Cited by 26
Self-citationLiao, S.-H., Yang, H.-C., Horng, H. E., & Yang, S. (2008) · Superconductor Science and Technology · doi:10.1088/0953-2048/22/2/025003 · Cited by 24
Knappe-Grüneberg, S., Schnabel, A., Wübbeler, G., & Burghoff, M. (2008) · Journal of Applied Physics · doi:10.1063/1.2837876 · Cited by 24
Self-citationLee, S.-J., Kim, K., Kang, C. S., Hwang, S. M., & Lee, Y. (2010) · Superconductor Science and Technology · doi:10.1088/0953-2048/23/11/115008 · Cited by 22
Calculation of an optimized design of magnetic shields with integrated demagnetization coils
Sun, Z., Schnabel, A., Burghoff, M., & Li, L. (2016) · AIP Advances · doi:10.1063/1.4960329 · Cited by 22
Self-citationAdvances in biomagnetic research using high-Tcsuperconducting quantum interference devices
Yang, H.-C., Horng, H. E., Yang, S., & Liao, S.-H. (2009) · Superconductor Science and Technology · doi:10.1088/0953-2048/22/9/093001 · Cited by 22
Vogel, M. W., Giorni, A., Vegh, V., Pellicer-Guridi, R., & Reutens, D. C. (2016) · PLoS ONE · doi:10.1371/journal.pone.0157040 · Cited by 21
Liao, S.-H., Yang, H.-C., Horng, H. E., Chen, H.-H., Yang, S., Chen, M.-J., & Yang, C.-H. (2008) · Journal of Applied Physics · doi:10.1063/1.2982092 · Cited by 19
Dong, H., Wang, Y., Zhang, S., Sun, Y., & Xie, X. (2008) · Superconductor Science and Technology · doi:10.1088/0953-2048/21/11/115009 · Cited by 18
Chen, H.-H., Yang, H.-C., Horng, H. E., Liao, S.-H., Yang, S. Y., & Wang, L.-M. (2011) · Journal of Applied Physics · doi:10.1063/1.3656984 · Cited by 17
WITHDRAWN: SQUID-detected ultra-low field MRI
Espy, M. A., Matlashov, A. N., & Volegov, P. L. (2012) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2012.11.030 · Cited by 17
“For a fixed relative homogeneity, the NMR line width scales linearly with the strength of the measurement magnetic field [24,25].”
BackgroundRetractedSub-millimetric ultra-low-field MRI detected in situ by a dressed atomic magnetometer
Bevilacqua, G., Biancalana, V., Dancheva, Y., & Vigilante, A. (2019) · Applied Physics Letters · doi:10.1063/1.5123653 · Cited by 16
SQUID-Based Low Field MRI System for Small Animals
Hatta, J., Miyamoto, M., Adachi, Y., Kawai, J., Uehara, G., & Kado, H. (2010) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2010.2091101 · Cited by 15
“The transverse relaxation time, , is shorter than water , which may be attributed to the absolute inhomogeneity of the measurement field [12].”
BackgroundNMR Spectroscopy for Chemical Analysis at Low Magnetic Fields
Glöggler, S., Blümich, B., & Appelt, S. (2011) · Topics in current chemistry · doi:10.1007/128_2011_304 · Cited by 15
“Among these are NMR detection by SQUID technology, which has widely been explored recently for spectroscopy and imaging [3, 12, 13], atomic magnetometers, for NMR detection”
MethodRestoring Narrow Linewidth to a Gradient-Broadened Magnetic Resonance by Inhomogeneous Dressing
Bevilacqua, G., Biancalana, V., Dancheva, Y. V., & Vigilante, A. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.11.024049 · Cited by 15
Körber, R., Casey, A. J., Shibahara, A., Piscitelli, M., Cowan, B. P., Lusher, C. P., Saunders, J., Drung, D., & Schurig, T. (2007) · Applied Physics Letters · doi:10.1063/1.2794028 · Cited by 14
Cooling a magnetic resonance force microscope via the dynamical back action of nuclear spins
Greenberg, Y. S., Il’ichev, E. V., & Nori, F. (2009) · Physical Review B · doi:10.1103/physrevb.80.214423 · Cited by 13
Improved determination of FID signal parameters in low-field NMR
Dabek, J., Nieminen, J. O., Vesanen, P. T., SEPPONEN, R. E., & Ilmoniemi, R. J. (2010) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2010.04.013 · Cited by 13
Kaseman, D. C., Janicke, M. T., Frankle, R. K., Nelson, T., Angles-Tamayo, G. F., Batrice, R. J., Magnelind, P. E., Espy, M. A., & Williams, R. F. (2020) · Applied Sciences · doi:10.3390/app10113836 · Cited by 12
Yang, H. C., Huang, K., Liao, S. H., Horng, H. E., Chieh, J.-J., Chen, H. H., Chen, M., Chen, K. L., & Wang, L.-M. (2013) · Applied Physics Letters · doi:10.1063/1.4774291 · Cited by 12
Femtotesla atomic magnetometer for zero- and ultralow-field nuclear magnetic resonance
Hong, T., Wang, Y., Shao, Z., Li, Q., Jiang, M., & Peng, X. (2024) · Magnetic Resonance Letters · doi:10.1016/j.mrl.2024.200170 · Cited by 11
Yang, H.-C., Liu, C.-W., Liao, S. H., Chen, H.-H., Chen, M. J., Chen, K. L., Horng, H.-E., Yang, S. Y., & Wang, L.-M. (2012) · Applied Physics Letters · doi:10.1063/1.4718032 · Cited by 11
Chen, K.-L., Hsu, C.-W., Yue-Bai, K., Chen, H.-H., Liao, S.-H., Wang, L.-M., Horng, H. E., & Yang, H.-C. (2013) · Superconductor Science and Technology · doi:10.1088/0953-2048/26/11/115008 · Cited by 11
Hartwig, S., Albrecht, H.-H., Scheer, H.-J., Burghoff, M., & Trahms, L. (2012) · Applied Magnetic Resonance · doi:10.1007/s00723-012-0387-9 · Cited by 10
Self-citationŽnidarič, M., Kozinc, Ž., & Škrinjar, D. (2023) · European Journal of Translational Myology · doi:10.4081/ejtm.2023.11894 · Cited by 10
Microtesla NMR and High Resolution MR Imaging Using High-$T_{\rm c}$ SQUIDs
Liao, S.-H., Chen, H. H., Deng, Y.-S., Wang, M., Chen, K. L., Liu, C. W., Liu, C. I., Yang, H.-C., Horng, H. E., Chieh, J.-J., et al. (2013) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2013.2237732 · Cited by 10
Kang, C. S., Kim, K., Lee, S.-J., Hwang, S. M., Kim, J., Yu, K. K., Kwon, H., Lee, S. K., & Lee, Y. (2011) · Journal of Applied Physics · doi:10.1063/1.3626826 · Cited by 10
The natural line width of low field nuclear magnetic resonance spectra
Harcken, H., Ketzler, R., Albrecht, M., Burghoff, M., Hartwig, S., & Trahms, L. (2010) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2010.06.008 · Cited by 10
Self-citationHigh-Performance Low-Field NMR Utilizing a High-$T_{\rm c}$ rf SQUID
Qiu, L. Q., Zhang, Y., Krause, H., Braginski, A. I., Tanaka, S., & Offenhäusser, A. (2009) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2009.2019560 · Cited by 10
“investigated the -coupling spectra of some liquid samples in the nanotesla range [5], [8].”
BackgroundSQUID-detected NMR in Earth's magnetic field
Qiu, L. Q., Zhang, Y., Krause, H., & Braginski, A. I. (2008) · Journal of Physics Conference Series · doi:10.1088/1742-6596/97/1/012026 · Cited by 8
Nieminen, J. O., Voigt, J., Hartwig, S., Scheer, H.-J., Burghoff, M., Trahms, L., & Ilmoniemi, R. J. (2013) · Metrology and Measurement Systems · doi:10.2478/mms-2013-0028 · Cited by 8
Self-citationULF-NMR system using HTS-SQUID and permanent magnet
Shohei, F., Tsunaki, S., Chigasaki, T., Hatsukade, Y., & Tanaka, S. (2012) · Physica C Superconductivity · doi:10.1016/j.physc.2012.03.014 · Cited by 8
Magnetic Resonance at or below the Earth's Magnetic Field
Thiele, C. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200700730 · Cited by 9
Huang, K. W., Chen, H. H., Yang, H. C., Horng, H. E., Liao, S. H., Chieh, J.-J., & Yang, S. (2012) · Journal of Instrumentation · doi:10.1088/1748-0221/7/06/p06005 · Cited by 7
“The results are close to the reported data [15, 16]”
ResultKaseman, D. C., Magnelind, P. E., Paisner, S. W., Yoder, J. L., Alvarez, M. A., Urbaitis, A. V., Janicke, M. T., Nath, P., Espy, M. A., & Williams, R. F. (2020) · Review of Scientific Instruments · doi:10.1063/1.5130391 · Cited by 7
Liao, S.-H., Liu, C.-W., Yang, H.-C., Chen, H.-H., Chen, M.-J., Chen, K.-L., Horng, H. E., Wang, L.-M., & Yang, S. (2012) · Applied Physics Letters · doi:10.1063/1.4723842 · Cited by 6
Huang, K., Liao, S.-H., Yang, H.-C., Chen, H.-H., Horng, H. E., Chen, M., & Yang, S. (2010) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2010.2083617 · Cited by 6
Lee, S.-J., Yu, K. K., Hwang, S.-M., Oh, S., Song, N. W., Jung, H., Han, O. H., & Shim, J. H. (2023) · ACS Omega · doi:10.1021/acsomega.3c05128 · Cited by 5
Chen, H.-H., Yang, H.-C., Horng, H. E., Liao, S. H., Yang, S., Chen, K. L., Wang, L.-M., & Chen, M. (2010) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2010.2084057 · Cited by 5
Hunter, M. W. (2012) · Annual reports on NMR spectroscopy · doi:10.1016/b978-0-12-397019-0.00004-2 · Cited by 5
Huang, X., Dong, H., Tao, Q., Yu, M., Li, Y., Rong, L., Krause, H., Offenhäusser, A., & Xie, X. (2019) · Sensors · doi:10.3390/s19163566 · Cited by 5
Ultra-Low-Field MRI and Its Combination with MEG
Parkkonen, L. T., Ilmoniemi, R. J., Lin, F., & Espy, M. A. (2014) · Springer eBooks · doi:10.1007/978-3-642-33045-2_46 · Cited by 4
Qiu, L., Liu, C., Dong, H., Xu, L., Zhang, Y., Krause, H., Xie, X., & Offenhäusser, A. (2012) · Chinese Physics Letters · doi:10.1088/0256-307x/29/10/107601 · Cited by 4
Superconductors in SQUID-Based Ultralow Field NMR—Flux-Trapping in Type-II Wires
Hwang, S.-M., Körber, R., Kim, K., Yu, K. K., Lee, S.-J., Shim, J. H., & Burghoff, M. (2014) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2014.2363623 · Cited by 4
“Such eddy currents can generate a transient remanent magnetic field, which can distort the μT-level measurement field (Bm) that should be highly uniform in the sample space [9], [10], even after Bp has been completely ramped down.”
BackgroundSelf-citationRelaxation of biofunctionalized magnetic nanoparticles in ultra-low magnetic fields
Yang, H. C., Chiu, L. L., Liao, S. H., Chen, H. H., Horng, H. E., Liu, C. W., Liu, C. I., Chen, K. L., Chen, M., & Wang, L.-M. (2013) · Journal of Applied Physics · doi:10.1063/1.4789009 · Cited by 3
Liao, S. H., Yang, H.-C., Horng, H. E., Liu, C. W., Chen, H. H., Chen, M. J., Chen, K. L., Liu, C. I., & Wang, L.-M. (2012) · Journal of Applied Physics · doi:10.1063/1.4770304 · Cited by 3
Prototype phantoms for characterization of ultralow field magnetic resonance imaging
Boss, M. A., Mates, J. A. B., Busch, S. E., SanGiorgio, P., Russek, S. E., Buckenmaier, K., Irwin, K. D., Cho, H.-M., Hilton, G. C., & Clarke, J. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25060 · Cited by 3
The Effect of Low Frequency Disturbance to SQUID Based Low Field NMR
Qiu, L., Krause, H., Zhang, Y., Dong, H., Braginski, A. I., & Offenhäusser, A. (2009) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2009.2019559 · Cited by 3
Hartwig, S. (2011) · Common Library Network (Der Gemeinsame Bibliotheksverbund) · Cited by 3
Self-citationField-Cycling NMR bei extrem kleinen Larmor-Frequenzen – Entwicklung und Anwendung
Kresse, B. (2016) · Technischen Universität Darmstadt · doi:10.26083/tuprints-00005824 · Cited by 3
Study of Cu-wound Flux transformer for High-Tc SQUID Ultra-Low Field MRI
Tanaka, S., Murata, H., Imamura, K., & Hatsukade, Y. (2014) · Journal of Physics Conference Series · doi:10.1088/1742-6596/507/4/042042 · Cited by 2
Ultralow magnetic fields elicit unexplained spin dynamics in water
Smart, A. G. (2011) · Physics Today · doi:10.1063/pt.3.1280 · Cited by 2
Yang, H.-C., Liao, S. H., Liu, C.-W., Chen, H.-H., Horng, H. E., Chen, K. L., Chen, M., Liu, C., & Wang, L.-M. (2012) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2012.2237000 · Cited by 2
Using ultra-low field nuclear magnetic resonance for direct neural current measurements
Matlachov, A. N., Volegov, P. L., Zotev, V. S., Espy, M. A., Mosher, J. C., & Kraus, R. H. (2007) · International Congress Series · doi:10.1016/j.ics.2007.01.022 · Cited by 2
Adamson, M. W. (1995) · Sudhoffs Archiv · Cited by 2
Femtotesla Atomic Magnetometer for Zero- and Ultralow-field Nuclear Magnetic ResonancePreprint
Hong, T., Wang, Y., Shao, Z., Li, Q., Jiang, M., & Peng, X. (2024) · arXiv (Cornell University) · doi:10.48550/arxiv.2403.01917 · Cited by 2
Liao, S.-H., Chieh, J.-J., Chou, Y.-T., Wang, M., Chen, H.-H., Huang, K., Yang, H.-C., & Horng, H. E. (2015) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2015.2393633 · Cited by 1
Magnetische Resonanz im Erdmagnetfeld oder darunter
Thiele, C. M. (2007) · Angewandte Chemie · doi:10.1002/ange.200700730 · Cited by 1
Combined ultra-low-field MRI and MEG: instrumentation and applications
Vesanen, P. T. (2013) · Aaltodoc (Aalto University) · Cited by 1
Ruede, F. (2009) · DepositOnce · doi:10.14279/depositonce-2073 · Cited by 1
Liebl, M. (2017) · Common Library Network (Der Gemeinsame Bibliotheksverbund) · Cited by 1
Method development for ultra-low-field magnetic resonance imaging and magnetoencephalography
Dabek, J. (2014) · Aaltodoc (Aalto University) · Cited by 1
Pellicer-Guridi, R. (2018) · The University of Queensland · doi:10.14264/uql.2018.707 · Cited by 1
Femtotesla Atomic Magnetometer for Zero- and Ultralow-Field Nuclear Magnetic ResonancePreprint
Hong, T., Wang, Y., Shao, Z., Li, Q., Jiang, M., & Peng, X. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4791191 · Cited by 1
Realization of current density imaging using ultra-low-field MRI
Hömmen, P. (2021) · Common Library Network (Der Gemeinsame Bibliotheksverbund) · doi:10.22032/dbt.49343 · Cited by 1
Superconductive Passive Devices
Khare, N., Belomestnykh, S. A., Padamsee, H. S., Brazdeikis, A., Wosik, J., & Claycomb, J. R. (2015) · Wiley eBooks · doi:10.1002/9783527670635.ch6
Metadata
- Authors
- Burghoff, M., Hartwig, S., Trahms, L., & Bernarding, J.
- Affiliations
- Physikalisch-Technische Bundesanstalt (DE)
- Otto-von-Guericke-Universität Magdeburg (DE)
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2005-07-27
- Volume
- 87
- Issue
- 5
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2061854868
- Cited by
- 101
- References
- 10
- Citations by year
- 2026: 1 · 2024: 2 · 2023: 2 · 2020: 2 · 2019: 7 · 2018: 2 · 2017: 2 · 2016: 5 · 2015: 2 · 2014: 4 · 2013: 10 · 2012: 10
- FWCI
- 4.07
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Physics Letters (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced NMR Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › NMR spectroscopy and applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Keywords
- nuclear magnetic resonance, spectral resolution, natural linewidth, distilled water
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.