BabySQUID: A mobile, high-resolution multichannel magnetoencephalography system for neonatal brain assessment

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

We developed a prototype of a mobile, high-resolution, multichannel magnetoencephalography (MEG) system, called babySQUID, for assessing brain functions in newborns and infants. Unlike electroencephalography, MEG signals are not distorted by the scalp or the fontanels and sutures in the skull. Thus, brain activity can be measured and localized with MEG as if the sensors were above an exposed brain. The babySQUID is housed in a moveable cart small enough to be transported from one room to another. To assess brain functions, one places the baby on the bed of the cart and the head on its headrest with MEG sensors just below. The sensor array consists of 76 first-order axial gradiometers, each with a pickup coil diameter of 6mm and a baseline of 30mm, in a high-density array with a spacing of 12–14mm center-to-center. The pickup coils are 6±1mm below the outer surface of the headrest. The short gap provides unprecedented sensitivity since the scalp and skull are thin (as little as 3–4mm altogether) in babies. In an electromagnetically unshielded room in a hospital, the field sensitivity at 1kHz was ∼17fT∕√Hz. The noise was reduced from ∼400to200fT∕√Hz at 1Hz using a reference cancellation technique and further to ∼40fT∕√Hz using a gradient common mode rejection technique. Although the residual environmental magnetic noise interfered with the operation of the babySQUID, the instrument functioned sufficiently well to detect spontaneous brain signals from babies with a signal to noise ratio (SNR) of as much as 7.6:1. In a magnetically shielded room, the field sensitivity was 17fT∕√Hz at 20Hz and 30fT∕√Hz at 1Hz without implementation of reference or gradient cancellation. The sensitivity was sufficiently high to detect spontaneous brain activity from a 7month old baby with a SNR as much as 40:1 and evoked somatosensory responses with a 50Hz bandwidth after as little as four averages. We expect that both the noise and the sensor gap can be reduced further by approximately half with a gain in SNR of about four. Thus, we conclude from the performance of the prototype that it should be feasible to improve the babySQUID to detect cortical activity in infants in real time with high spatial resolution.

Overview

Integrity signals

Registry

Crossref · 10.1063/1.2168672

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 5

  1. 2000, Neuorology of the Newborn
  2. 2005, Clin. Neurophysiol., 116, 1142
  3. 1999, Electroencephalogr. Clin. Neurophysiol., 110, 230
  4. 1997, J. Japanese Biomag. Bioelectromag. Soc., 10, 180
  5. 2004, Brain Topogr, 16, 269

Cited by

See all 53

Metadata

Authors
Okada, Y., Pratt, K., Atwood, C., Mascarenas, A., Reineman, R., Nurminen, J., & Paulson, D.
Affiliations
  • University of New Mexico (US)
  • Tristan Technologies (United States) (US)
  • Helsinki University Hospital (FI)
Venue
Review of Scientific Instruments
Published
2006-02-01
Volume
77
Issue
2
ISSN
  • 0034-6748 (ISSN-L)
  • 1089-7623
OpenAlex
W2084082143
Cited by
53
References
14
Citations by year
2026: 1 · 2025: 2 · 2024: 2 · 2023: 1 · 2022: 1 · 2021: 2 · 2020: 3 · 2019: 6 · 2018: 3 · 2017: 5 · 2016: 4 · 2015: 5 · 2014: 6 · 2013: 2
FWCI
1.29
Type
journal article
Language
en
Open access
closed
Locations
Review of Scientific Instruments (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
Keywords
magnetoencephalography, infant brain activity, axial gradiometer, high-density sensor arrays, magnetic noise, field sensitivity, somatosensory evoked potentials, spontaneous brain activity, magnetic shielding, SQUID magnetometer, infant neuroimaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.