The DOI matches its Crossref record.
Development of liquid-environment frequency modulation atomic force microscope with low noise deflection sensor for cantilevers of various dimensions
Abstract
We have developed a liquid-environment frequency modulation atomic force microscope (FM-AFM) with a low noise deflection sensor for a wide range of cantilevers with different dimensions. A simple yet accurate equation describing the theoretical limit of the optical beam deflection method in air and liquid is presented. Based on the equation, we have designed a low noise deflection sensor. Replaceable microscope objective lenses are utilized for providing a high magnification optical view (resolution: <3μm) as well as for focusing a laser beam (laser spot size: ∼10μm). Even for a broad range of cantilevers with lengths from 35to125μm, the sensor provides deflection noise densities of less than 11fm∕Hz in air and 16fm∕Hz in water. In particular, a cantilever with a length of 50μm gives the minimum deflection noise density of 5.7fm∕Hz in air and 7.3fm∕Hz in water. True atomic resolution of the developed FM-AFM is demonstrated by imaging mica in water.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
High-speed atomic force microscopy for nano-visualization of dynamic biomolecular processes
Ando, T., Uchihashi, T., & Fukuma, T. (2008) · Progress in Surface Science · doi:10.1016/j.progsurf.2008.09.001 · Cited by 558
Self-citationFukuma, T., Ueda, Y., Yoshioka, S., & Asakawa, H. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.016101 · Cited by 464
Self-citationHigh-speed AFM and nano-visualization of biomolecular processes
Ando, T., Uchihashi, T., Kodera, N., Yamamoto, D., Miyagi, A., Taniguchi, M., & Yamashita, H. (2008) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-007-0406-0 · Cited by 262
Fukuma, T., Reischl, B., Kobayashi, N., Spijker, P., Canova, F. F., Miyazawa, K., & Foster, A. S. (2015) · Physical Review B · doi:10.1103/physrevb.92.155412 · Cited by 126
Self-citationBaimpos, T., Shrestha, B. R., Raman, S., & Valtiner, M. (2014) · Langmuir · doi:10.1021/la500288w · Cited by 94
Metadata
- Authors
- Fukuma, T., & Jarvis, S. P.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2006-04-01
- Volume
- 77
- Issue
- 4
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2062713357
- Cited by
- 193
- References
- 0
- FWCI
- 6.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of liquid-environment frequency modulation atomic force microscope with low noise deflection sensor for cantilevers of various dimensions. https://app.cochat.ai/papers/10.1063/1.2188867
- The paper
- Fukuma, T., & Jarvis, S. P. (2006). Development of liquid-environment frequency modulation atomic force microscope with low noise deflection sensor for cantilevers of various dimensions. Review of Scientific Instruments. https://doi.org/10.1063/1.2188867
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.