Measurement of the Emissivity of Clean and Contaminated Silver Plated Copper Surfaces at Cryogenic Temperatures
Abstract
An experiment has been designed, fabricated, and conducted to measure emissivity of clean and contaminated metallic surfaces at temperatures between 25 K and 35 K. Samples of silver‐plated copper with a total surface area of 0.25 m2 are secured to the coldhead of a single stage cryocooler and enclosed within an effective black thermal shield, which has an effective emissivity of 0.95 and temperatures between 275 K and 280 K. From error analysis, a sample with an emissivity of 0.020 had an experimental error between +/− 0.001 and +/− 0.002. From measurement of the radiation heat transfer, the emissivity at 30 K was 45% of the emissivity that was measured at 300 K for a set of silver‐plated copper samples. In addition, 110 μg of water vapor was sufficient to increase the emissivity of the silver‐plated copper between 50% and 200%.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The field has seen a gradual shift from liquid-cryogen baths to refrigeration-based cooling systems for cryogenic emissivity measurements.
“With respect to cooling techniques, the field has seen a gradual shift from liquid-cryogen baths [13,33,36,42,45,46,53] to refrigeration-based cooling systems [16,43,47,51,52].”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [47]
Duckworth et al. found that even minimal quantities of water vapor can induce a substantial enhancement in the surface emissivity of silver-plated copper, with a maximum increase up to fourfold.
“The experimental findings indicated that even minimal quantities of water vapor were capable of inducing a substantial enhancement in the surface emissivity of silver-plated copper, with the maximum increase observed reaching up to fourfold.”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [47]
Citations
Cited by
Sorted by citations
Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review
Li, B., & Shen, F. (2026) · Cryo · doi:10.3390/cryo2010004 · Cited by 1
Metadata
- Authors
- Duckworth, R. C.
- Venue
- AIP Conference Proceedings
- Publisher
- AIP
- Published
- 2006
- Volume
- 824
- Pages
- 61-68
- ISSN
- 0094-243X
- Cited by
- 8
- References
- 0
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review