The DOI matches its Crossref record.
Ferromagnetic resonance linewidth in metallic thin films: Comparison of measurement methods
Abstract
Stripline (SL), vector network analyzer (VNA), and pulsed inductive microwave magnetometer (PIMM) techniques were used to measure the ferromagnetic resonance (FMR) linewidth for a series of Permalloy films with thicknesses of 50 and 100nm. The SL-FMR measurements were made for fixed frequencies from 1.5to5.5GHz. The VNA-FMR and PIMM measurements were made for fixed in-plane fields from 1.6to8kA∕m (20–100Oe). The results provide a confirmation, lacking until now, that the linewidths measured by these three methods are consistent and compatible. In the field format, the linewidths are a linear function of frequency, with a slope that corresponds to a nominal Landau-Lifshitz phenomenological damping parameter α value of 0.007 and zero frequency intercepts in the 160–320A∕m (2–4Oe) range. In the frequency format, the corresponding linewidth versus frequency response shows a weak upward curvature at the lowest measurement frequencies and a leveling off at high frequencies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kruglyak, V. V., Demokritov, S. O., & Grundler, D. (2010) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/43/26/264001 · Cited by 1,486
Zhang, W., Han, W., Jiang, X., Yang, S.-H., & S. P. Parkin, S. (2015) · Nature Physics · doi:10.1038/nphys3304 · Cited by 580
Scaling of Spin Hall Angle in 3d, 4d, and 5d Metals from Y 3 Fe 5 O 12 /Metal Spin Pumping
Wang, H. L., Du, C. H., Pu, Y., Adur, R., Hammel, P. C., & Yang, F. Y. (2014) · Physical Review Letters · doi:10.1103/physrevlett.112.197201 · Cited by 557
Magnonic crystals for data processing
Chumak, A. V., Serga, A. A., & Hillebrands, B. (2017) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/aa6a65 · Cited by 457
Introduction to spin wave computing
Mahmoud, A., Ciubotaru, F., Vanderveken, F., Chumak, A. V., Hamdioui, S., Adelmann, C., & Cotofana, S. (2020) · Journal of Applied Physics · doi:10.1063/5.0019328 · Cited by 354
Antiferromagnonic Spin Transport fromY3Fe5O12into NiO
Wang, H., Du, C., Hammel, P. C., & Yang, F. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.097202 · Cited by 350
Micro-focused Brillouin light scattering: imaging spin waves at the nanoscale
Sebastian, T., Schultheiss, K., Obry, B., Hillebrands, B., & Schultheiss, H. (2015) · Frontiers in Physics · doi:10.3389/fphy.2015.00035 · Cited by 325
Jamali, M., Lee, J. S., Jeong, J. S., Mahfouzi, F., Lv, Y., Zhao, Z., Nikolić, B. K., Mkhoyan, K. A., Samarth, N., & Wang, J.-P. (2015) · Nano Letters · doi:10.1021/acs.nanolett.5b03274 · Cited by 314
Metadata
- Authors
- Kalarickal, S. S., Krivosik, P., Wu, M., Patton, C. E., Schneider, M. L., Kabos, P., Silva, T. J., & Nibarger, J. P.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 2006-05-01
- Volume
- 99
- Issue
- 9
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2048807660
- Cited by
- 602
- References
- 0
- FWCI
- 6.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.