Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 395

The DOI matches its Crossref record.

An experimental study of drop-on-demand drop formation

Dong, Hongming, Carr, Wallace W., Morris, Jeffrey F.·2006·Physics of Fluids

Abstract

The dynamics of drop-on-demand (DOD) drop formation have been studied experimentally using an imaging system with an interframe time of 1μs and a spatial resolution of 0.81μm∕pixel. Using a piezoelectrical actuated inkjet printhead with the nozzle orifice diameter of 53μm, experiments were conducted over a range of viscosities (1.0–5.0cP) and surface tensions (35–73mN∕m). The effects of the driving signal, which controls the piezoelectric transducer that produces the pressure pulse to drive the liquid from the reservoir through the orifice, have been examined along with those of liquid properties. The main stages of DOD drop formation, including ejection and stretching of liquid, pinch-off of liquid thread from the nozzle exit, contraction of liquid thread, breakup of liquid thread into primary drop and satellites, and recombination of primary drop and satellites, are analyzed based on the experimental results. The breakup time of liquid threads was found to be dependent mainly on the capillary time based on the length scale of the nozzle orifice and the growth rate of the most unstable disturbance normalized by the inverse of the capillary time. However, a well-designed waveform of driving signal can initiate an abrupt pinch-off of the liquid thread from the nozzle exit. During the contraction of the liquid thread after it has pinched off from the nozzle, two modes of breakup were observed: end-pinching where the liquid thread pinches off from an almost spherical head, and multiple breakup due to capillary waves. The effects of liquid and system parameters on the formation and recombination of the primary drop and satellites were investigated. Based on experimental observations, a necessary condition for the recombination of the primary drop and satellite and the limit for liquid thread length without breakup during contraction are proposed. The primary drop size increases slightly with increasing surface tension and/or decreasing viscosity. The driving voltage to the piezoelectric transducer mainly determines whether satellite formation will occur and the size of satellites, and it has insignificant effect on primary drop size.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.2217929

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 395

Metadata

Authors
Dong, H., Carr, W. W., & Morris, J. F.
Venue
Physics of Fluids
Published
2006-07-01
Volume
18
Issue
7
ISSN
  • 1070-6631 (ISSN-L)
  • 1089-7666
OpenAlex
W2069319309
Cited by
395
References
0
FWCI
16.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An experimental study of drop-on-demand drop formation. https://app.cochat.ai/papers/10.1063/1.2217929
The paper
Dong, H., Carr, W. W., & Morris, J. F. (2006). An experimental study of drop-on-demand drop formation. Physics of Fluids. https://doi.org/10.1063/1.2217929

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.