The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Pressure calibration of diamond anvil Raman gauge to 310GPa
Abstract
In order to develop an optical method for pressure determination in the multimegabar region, the first-order Raman spectra of diamond anvils were investigated at pressures up to 310GPa. The high-frequency edge of the Raman band, which corresponds to the Raman shift of the anvil culet due to the normal stress, was calibrated against the sample pressure derived from the equation of state of Pt. The obtained pressure dependence of the edge frequency demonstrates the reliability of this diamond anvil Raman gauge. Up to the maximum pressure of this study, the relation between Raman frequency and normal stress at the diamond anvil culet is formally similar to the equation of state of a hydrostatically compressed isotropic elastic body having a bulk modulus of K0=547(11)GPa and a pressure derivative of the bulk modulus K0′=3.75(20).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mao, H. K., Bell, P. M., Shaner, J. W., & Steinberg, D. J. (1978) · Journal of Applied Physics · doi:10.1063/1.325277 · Cited by 2,280
The equation of state of platinum to 660 GPa (6.6 Mbar)
Holmes, N. C., Moriarty, J. A., Gathers, G. R., & Nellis, W. J. (1989) · Journal of Applied Physics · doi:10.1063/1.344177 · Cited by 554
Properties of diamond under hydrostatic pressures up to 140 GPa
Occelli, F., Loubeyre, P., & LeToullec, R. (2003) · Nature Materials · doi:10.1038/nmat831 · Cited by 502
Optical studies of solid hydrogen to 320 GPa and evidence for black hydrogen
Loubeyre, P., Occelli, F., & LeToullec, R. (2002) · Nature · doi:10.1038/416613a · Cited by 414
Evidence of a fcc-hcp Transition in Aluminum at Multimegabar Pressure
Akahama, Y., Nishimura, M., Kinoshita, K., Kawamura, H., & Ohishi, Y. (2006) · Physical Review Letters · doi:10.1103/physrevlett.96.045505 · Cited by 180
Self-citationMegabar high‐pressure cells for Raman measurements
Eremets, M. I. (2003) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1044 · Cited by 87
Convenient optical pressure gauge for multimegabar pressures calibrated to 300GPa
Sun, L., Ruoff, A. L., & Stupian, G. W. (2004) · Applied Physics Letters · doi:10.1063/1.1840117 · Cited by 43
Cited by
A stable compound of helium and sodium at high pressure
Dong, X., Oganov, A. R., Goncharov, A. F., Stavrou, E., Lobanov, S., Saleh, G., Qian, G.-R., Zhu, Q., Gatti, C., Deringer, V. L., et al. (2017) · Nature Chemistry · doi:10.1038/nchem.2716 · Cited by 386
Pressure-Induced Metallization of Molybdenum Disulfide
Chi, Z.-H., Zhao, X.-M., Zhang, H., Goncharov, A. F., Lobanov, S. S., Kagayama, T., Sakata, M., & Chen, X.-J. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.036802 · Cited by 309
Robust zero resistance in a superconducting high-entropy alloy at pressures up to 190 GPa
Guo, J., Wang, H., von Rohr, F., Wang, Z., Cai, S., Zhou, Y., Yang, K., Li, A., Jiang, S., Wu, Q., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1716981114 · Cited by 212
Metadata
- Authors
- Akahama, Y., & Kawamura, H.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 2006-08-15
- Volume
- 100
- Issue
- 4
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2039617659
- Cited by
- 494
- References
- 7
- FWCI
- 3.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pressure calibration of diamond anvil Raman gauge to 310GPa. https://app.cochat.ai/papers/10.1063/1.2335683
- The paper
- Akahama, Y., & Kawamura, H. (2006). Pressure calibration of diamond anvil Raman gauge to 310GPa. Journal of Applied Physics. https://doi.org/10.1063/1.2335683
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.