The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Calibration of optical tweezers with positional detection in the back focal plane
Open accessAbstract
We explain and demonstrate a new method of force and position calibrations for optical tweezers with back-focal-plane photodetection. The method combines power spectral measurements of thermal motion and the response to a sinusoidal motion of a translation stage. It consequently does not use the drag coefficient of the trapped object as an input. Thus, neither the viscosity, nor the size of the trapped object, nor its distance to nearby surfaces needs to be known. The method requires only a low level of instrumentation and can be applied in situ in all spatial dimensions. It is both accurate and precise: true values are returned, with small error bars. We tested this experimentally, near and far from surfaces in the lateral directions. Both position and force calibrations were accurate to within 3%. To calibrate, we moved the sample with a piezoelectric translation stage, but the laser beam could be moved instead, e.g., by acousto-optic deflectors. Near surfaces, this precision requires an improved formula for the hydrodynamical interaction between an infinite plane and a microsphere in nonconstant motion parallel to it. We give such a formula.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the use of windows for harmonic analysis with the discrete Fourier transform
Harris, F. J. (1978) · Proceedings of the IEEE · doi:10.1109/proc.1978.10837 · Cited by 7,326
Direct observation of kinesin stepping by optical trapping interferometry
Svoboda, K., Schmidt, C. F., Schnapp, B. J., & Block, S. M. (1993) · Nature · doi:10.1038/365721a0 · Cited by 1,910
Cited by
Recent Advances in Optical Tweezers
Moffitt, J. R., Chemla, Y. R., Smith, S. B., & Bustamante, C. (2008) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.043007.090225 · Cited by 1,084
Optical tweezers in single-molecule biophysics
Bustamante, C. J., Chemla, Y. R., Liu, S., & Wang, M. D. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00021-6 · Cited by 615
The Complex Folding Network of Single Calmodulin Molecules
Stigler, J., Ziegler, F., Gieseke, A., Gebhardt, J. C. M., & Rief, M. (2011) · Science · doi:10.1126/science.1207598 · Cited by 372
External forces control mitotic spindle positioning
Fink, J., Carpi, N., Betz, T., Bétard, A., Chebah, M., Azioune, A., Bornens, M., Sykes, C., Fetler, L., Cuvelier, D., et al. (2011) · Nature Cell Biology · doi:10.1038/ncb2269 · Cited by 360
ATP-dependent mechanics of red blood cells
Betz, T., Lenz, M., Joanny, J.-F., & Sykes, C. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0904614106 · Cited by 324
Metadata
- Authors
- Tolić-Nørrelykke, S. F., Schäffer, E., Howard, J., Pavone, F. S., Jülicher, F., & Flyvbjerg, H.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2006-10-01
- Volume
- 77
- Issue
- 10
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2017312934
- Cited by
- 325
- References
- 2
- FWCI
- 7.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Calibration of optical tweezers with positional detection in the back focal plane. https://app.cochat.ai/papers/10.1063/1.2356852
- The paper
- Tolić-Nørrelykke, S. F., Schäffer, E., Howard, J., Pavone, F. S., Jülicher, F., & Flyvbjerg, H. (2006). Calibration of optical tweezers with positional detection in the back focal plane. Review of Scientific Instruments. https://doi.org/10.1063/1.2356852
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.