The DOI matches its Crossref record.
Organic-transistor-based flexible pressure sensors using ink-jet-printed electrodes and gate dielectric layers
Abstract
The authors have fabricated 33cm diagonal flexible pressure sensors using organic field-effect transistor (FET) active matrices. Polyimide precursors and silver nanoparticles are patterned on a polyimide film by using an ink-jet printing system and cured at 180°C to form gate dielectric layers and electrodes for organic FETs, respectively. In order to define the device dimensions, epoxy partitions are prepared by a screen printing system. The mobility of the transistors is 0.7cm2∕Vs and the on/off ratio exceeds 106. Spatial distributions of pressure are read out by an organic FET active matrix.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Advances of flexible pressure sensors toward artificial intelligence and health care applications
Zang, Y., Zhang, F., Di, C.-A., & Zhu, D. (2015) · Materials Horizons · doi:10.1039/c4mh00147h · Cited by 1,272
Stretchable, Large‐area Organic Electronics
Sekitani, T., & Someya, T. (2010) · Advanced Materials · doi:10.1002/adma.200904054 · Cited by 773
Self-citationAn Overview of the Development of Flexible Sensors
Han, S., Peng, H., Sun, Q., Venkatesh, S., Chung, K., Lau, S. C., Zhou, Y., & Roy, V. A. L. (2017) · Advanced Materials · doi:10.1002/adma.201700375 · Cited by 771
Microstructured Graphene Arrays for Highly Sensitive Flexible Tactile Sensors
Zhu, B., Niu, Z., Wang, H., Leow, W. R., Wang, H., Li, Y., Zheng, L., Wei, J., Huo, F., & Chen, X. (2014) · Small · doi:10.1002/smll.201401207 · Cited by 632
Soft Manipulators and Grippers: A Review
Hughes, J., Culha, U., Giardina, F., Guenther, F., Rosendo, A., & Iida, F. (2016) · Frontiers in Robotics and AI · doi:10.3389/frobt.2016.00069 · Cited by 619
Flexible suspended gate organic thin-film transistors for ultra-sensitive pressure detection
Zang, Y., Zhang, F., Huang, D., Gao, X., Di, C.-A., & Zhu, D. (2015) · Nature Communications · doi:10.1038/ncomms7269 · Cited by 548
Review of MXene electrochemical microsupercapacitors
Jiang, Q., Lei, Y., Liang, H., Xi, K., Xia, C., & Alshareef, H. N. (2020) · Energy Storage Materials · doi:10.1016/j.ensm.2020.01.018 · Cited by 397
Chemical formation of soft metal electrodes for flexible and wearable electronics
Wang, D., Zhang, Y., Lu, X., Ma, Z., Xie, C., & Zheng, Z. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00192d · Cited by 307
Recent Progress in Aromatic Polyimide Dielectrics for Organic Electronic Devices and Circuits
Ji, D., Li, T., Hu, W., & Fuchs, H. (2019) · Advanced Materials · doi:10.1002/adma.201806070 · Cited by 297
Electroless copper deposition: A critical review
Ghosh, S. (2019) · Thin Solid Films · doi:10.1016/j.tsf.2018.11.016 · Cited by 272
Huang, Y.-C., Liu, Y., Ma, C., Cheng, H.-C., He, Q., Wu, H., Wang, C., Lin, C.-Y., Huang, Y., & Duan, X. (2020) · Nature Electronics · doi:10.1038/s41928-019-0356-5 · Cited by 233
Active Devices Based on Organic Semiconductors for Wearable Applications
Barbaro, M., Caboni, A., Cosseddu, P., Mattana, G., & Bonfiglio, A. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2044798 · Cited by 60
Organic Thin Film Transistors in Mechanical Sensors
Lamport, Z. A., Cavallari, M. R., Kam, K. A., McGinn, C. K., Yu, C., & Kymissis, I. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202004700 · Cited by 40
Metadata
- Authors
- Noguchi, Y., Sekitani, T., & Someya, T.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2006-12-18
- Volume
- 89
- Issue
- 25
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1970845633
- Cited by
- 164
- References
- 0
- FWCI
- 11.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.